We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Advanced Imaging Technique Tracks Molecular Movement in Membranes of Living Cells

By LabMedica International staff writers
Posted on 20 Aug 2013
Cell biologists have combined two advanced imaging techniques to study the movement of molecules in the membranes of living cells and tissues.

Investigators at Karlsruhe Institute of Technology (Germany) combined raster image correlation spectroscopy (RICS) with stimulated emission depletion microscopy (STED) in imaging experiments on model membranes and live cells.

RICS is a powerful tool to study fast molecular dynamics such as protein diffusion or receptor–ligand interactions inside living cells and tissues. More...
By analyzing time dependent spatial correlations of fluorescence intensity fluctuations from raster-scanned microscopy images, molecular motions can be revealed in a spatially resolved manner. However, because of diffraction-limited optical resolution, conventional raster image-correlation spectroscopy can only distinguish larger regions of interest and requires low fluorophore concentrations in the nanomolar range.

To counter the limitations of RICS the investigators combined it with STED microscopy. A STED microscope is a fluorescence microscope where the light spot scanning the fluorescence image can be reduced considerably. This method has already been used successfully to reach a maximum resolution in the imaging of cells.

In the current study, which was published in the June 27, 2013, online edition of the journal Nature Communications, the investigators showed that STED-RICS microscopy offered enhanced multiplexing capability because of enhanced spatial resolution as well as access to 10–100 times higher fluorophore concentrations.

“This means that the STED-RICS method can be used to derive from any fluorescence image a highly resolved map of the number and movability of the marked molecules in the area scanned by the spot,” said senior author Dr. Gerd Ulrich Nienhaus, professor of applied physics at the Karlsruhe Institute of Technology.

Application of the STED-RICS technique will enable investigators to precisely and quantitatively track the movements of cell membrane lipids and receptors. The action of many drugs is linked to the interactions among these molecules. “About every second medical substance influences signal transduction of G-protein coupled receptors, an important subclass,” said Dr. Nienhaus.

Related Links:
Karlsruhe Institute of Technology


New
Gold Member
Hematology Analyzer
Medonic M32B
Serological Pipet Controller
PIPETBOY GENIUS
New
Capillary Blood Collection Tube
IMPROMINI M3
New
Blood Glucose Test Strip
AutoSense Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








DIASOURCE (A Biovendor Company)

Channels

Clinical Chemistry

view channel
Image: The steps involved in the electric field-induced capture and release (EFIRM) assay (Photo courtesy of UCLA School of Dentistry)

Saliva-Based Cancer Detection Technology Eliminates Need for Complex Sample Preparation

Early detection of cancer and other serious diseases is crucial for effective treatment and improved outcomes, yet current diagnostic methods often involve invasive procedures and complex sample preparation.... Read more

Molecular Diagnostics

view channel
Image: The Lumipulse G pTau217/ß-Amyloid 1-42 Plasma Ratio is FDA-cleared for use in diagnosing Alzheimer’s (Photo courtesy of Fujirebio)

First FDA Cleared Blood Test for Alzheimer’s Diagnosis Marks Turning Point in Early Detection

Alzheimer’s disease is a progressive form of dementia that affects memory, cognition, and behavior, eventually interfering with daily activities. Early and accurate diagnosis is essential to improving... Read more

Hematology

view channel
Image: CitoCBC is the world first cartridge-based CBC to be granted CLIA Waived status by FDA (Photo courtesy of CytoChip)

Disposable Cartridge-Based Test Delivers Rapid and Accurate CBC Results

Complete Blood Count (CBC) is one of the most commonly ordered lab tests, crucial for diagnosing diseases, monitoring therapies, and conducting routine health screenings. However, more than 90% of physician... Read more

Immunology

view channel
Image: The 3D paper-based analytical device has shown high clinical accuracy for adult-onset immunodeficiency (Photo courtesy of National Taiwan University)

Paper-Based Device Accurately Detects Immune Defects in 10 Minutes

Patients with hidden immune defects are especially vulnerable to severe and persistent infections, often due to autoantibodies that block interferon-gamma (IFN-γ), a key molecule in immune defense.... Read more

Microbiology

view channel
Image: The groundbreaking salmonella antimicrobial resistance prediction platform has demonstrated 95% accuracy (Photo courtesy of Yujie You et al., DOI: 10.1016/j.eng.2025.01.013)

New Platform Leverages AI and Quantum Computing to Predict Salmonella Antimicrobial Resistance

Antimicrobial-resistant Salmonella strains are a growing public health concern due to the overuse of antimicrobials and the rise of genetic mutations. Accurate prediction of resistance is crucial for effective... Read more

Technology

view channel
Image: The Check4 gene-detection platform (Photo courtesy of IdentifySensors)

Electronic Biosensors Used to Detect Pathogens Can Rapidly Detect Cancer Cells

A major challenge in healthcare is the early and affordable detection of serious diseases such as cancer. Early diagnosis remains difficult due to the complexity of identifying specific genetic markers... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.