We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Download Mobile App




Relación urinaria NAG-creatina predice enfermedad renal diabética avanzada

By LabMedica International staff writers
Posted on 04 Jan 2023

La diabetes es la principal causa de enfermedad renal crónica y enfermedad renal en etapa terminal en todo el mundo y se convierte en uno de los mayores desafíos de atención médica del siglo XXI. More...

Las complicaciones microvasculares se han identificado como las complicaciones diabéticas más comunes y mayores.

La nefropatía diabética (ND) generalmente manifiesta un deterioro progresivo de la función renal, y un aumento de la tasa de filtración glomerular (TFG), la hipertrofia glomerular y la excreción de albúmina urinaria son los principales indicadores. Varias proteínas de la orina pueden exhibir diferencias significativas en el poder diagnóstico, predictivo y pronóstico de la ERD.

Los científicos médicos de la Facultad de Medicina de Suzhou de la Universidad de Soochow (Suzhou, China) analizaron retrospectivamente un total de 117 pacientes con ND tipo 2, 83 hombres y 34 mujeres, de 37 a 85 años de edad, incluidas las etapas temprana y avanzada, y sus parámetros de laboratorio fueron evaluados estadísticamente. Los pacientes se dividieron en dos grupos: grupos tempranos (estadios IIa y IIb) y avanzados (estadios III y IV) según la clasificación patológica.

Se obtuvo la orina puntual y entera de 24 horas, y la sangre venosa en ayunas de los pacientes se recogió en tubos vacutainer. Se utilizó un analizador hematológico automático BC-7500 (Mindray Inc, Shenzhen, China) para analizar los glóbulos blancos (WBC), los neutrófilos (NEU) y la proteína C reactiva de alta sensibilidad (HS-CRP). Se midieron múltiples índices bioquímicos, que incluyeron creatina sérica (sCR), urea sérica (sUR), colesterol (CHOL), homocisteína (HCY), hormona estimulante tiroidea (TSH), triyodotironina libre (T3 libre), tiroxina libre (T4 libre), fibrinógeno (FIB) y dímero D (DD).

Se midieron los niveles de creatinina urinaria, N-acetil-β-d-glucosaminidasa (NAG), proteína total (PRO), microalbúmina (MA), inmunoglobulina G (IgG), transferrina (TFR) y α1-microglobulina (α1MG) en orina puntual y excreción de albúmina (EAU) en orina de 24 horas con el analizador bioquímico completamente automatizado AU5800 (Beckman-Coulter, Brea, CA, EUA). Las proporciones de N-acetil-β-d-glucosaminidasa (NAG) urinaria y proteínas a creatinina se calcularon para presentarse como NAG/CR, PRO/CR, proporción de albúmina a creatina (ACR), IgG/CR, TFR/CR y α1MG/ CR.

Los investigadores informaron que el nivel de N-acetil-β-d-glucosaminidasa-creatina (NAG/CR) en la ND avanzada fue estadísticamente más alto que en la ND temprana, y hubo una mayor incidencia de ND avanzada (72 % frente a 56 %) y cociente de probabilidades elevado (OR: 3,917) de NAG/RC con ≥2,79 U/mmol frente a <2,79 U/mmol. La relación NAG/CR también mostró un área bajo la curva ROC más alta de 0,727 con una sensibilidad alta (0,75) y una especificidad moderada (0,66) cuando se estableció como valor de corte óptimo 1,93 U/mmol. El análisis multivariable ajustado reveló que NAG/CR tenía un OR de 1,021 y 2,223 basado en una variable continua y categórica, respectivamente, para el riesgo de ND avanzada. Además, la prevalencia de ND avanzada exhibió una tendencia creciente por un incremento del trisector de NAG/CR.

Los autores concluyeron que la relación NAG/CR es un predictor independiente de la ND avanzada en pacientes con diabetes tipo 2 (DT2), y también se puede usar como un marcador de identificación poderoso entre la ND avanzada y la temprana. El estudio fue publicado el 26 de diciembre de 2022 en el Journal of Clinical Laboratory Analysis .

Enlaces relacionados:
Facultad de Medicina de Suzhou de la Universidad de Soochow
Mindray Inc.
Beckman-Coulter


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
Drug Testing Assays
Atellica DT 250 Analyzer
New
Gold Member
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Illustration of CNF-sheet-mediated membrane fusion between an extracellular vesicle and a lipid nanoparticle carrying molecular beacons for internal microRNA detection. (Image Credit: Kawaguchi et al., Cell Reports Physical Science, 2026. DOI: 10.1016/j.xcrp.2026.103613)

Single-Vesicle Analysis Reveals Tissue-Associated Inflammatory Signatures

Chronic inflammation can persist for months or years when immune cells continue attacking tissues despite the absence of an active threat. It is associated with cancers, brain disorders, autoimmune diseases,... Read more

Molecular Diagnostics

view channel
Image Credit: Adobe Stock

Comprehensive Tumor Profiling Uncovers Overlooked Hereditary Cancer Risk Genes

Patients with solid tumors often undergo molecular profiling to identify alterations that can guide therapy. This testing may also reveal constitutional cancer-predisposing DNA variants, which are present... Read more

Hematology

view channel
Image: These new ANC reference ranges can help clinicians more accurately interpret neutrophil counts, reduce unnecessary testing and treatment interruptions, and help support more equitable care. (Photo courtesy of the American Society of Hematology)

New Reference Ranges Clarify Normal Neutrophil Counts in Duffy-Null Patients

Duffy-null status is a common genetic trait associated with naturally lower circulating white blood cell counts. It affects about 10% of the U.S. population and more than 66% of people with African or... Read more

Immunology

view channel
Image: Study design and collection of lower respiratory tract lining fluid (RTLF) using the PExA instrument. (Aguilera K, Hober A, Greilert Norin N, et al. eBioMedicine, 2026. doi:10.1016/j.ebiom.2026.106538)

Exhaled Breath Particles Reveal Virus-Specific Antibodies in the Lower Airways

Respiratory viruses such as influenza virus, SARS-CoV-2, and respiratory syncytial virus (RSV) require immune protection across the airway mucosa. Antibodies in the respiratory tract lining are important... Read more

Microbiology

view channel
Image: Four-quadrant streaking of fecal samples on chromogenic UTI agar shows various patterns of relative bacterial species abundance. The assorted shapes of the pinkish colonies indicate different E. coli strains. (Photo courtesy of Sokurenko Lab)

Stool Testing Predicts UTI Risk and Guides Antibiotic Selection

Urinary tract infections (UTIs) are a common reason for antibiotic prescribing in general medical practice and can be painful in postmenopausal women, sometimes progressing to kidney infection or life-threatening... Read more

Pathology

view channel
AI: Artificial intelligence; CNN: Convolutional neural networks; ResNet: Residual neural network. (Xing-hua Gao from The First Hospital of China Medical University, China Image Source Link: https://www.ovid.com/jnls/cmj/fulltext/10.1097/cm9.0000000000004154~deep-learning-based-computational-pathology-technologies)

Review Highlights Progress and Validation Needs for AI in Digital Pathology

Pathology remains the gold standard for disease diagnosis, but clinical laboratories face growing demands for faster, more reproducible diagnostic and prognostic workflows. Digital pathology based on whole-slide... Read more

Industry

view channel
Image: Siemens Healthineers has begun carving out its in vitro diagnostics business as a standalone company named Olyrian Diagnostics (Photo courtesy of Siemens Healthineers)

Siemens Healthineers Begins Transition Toward Standalone Olyrian Diagnostics Business

Siemens Healthineers has begun carving out its in vitro diagnostics business, which will operate as Olyrian Diagnostics. The new name will be introduced in stages as the business prepares to become a standalone... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.