We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




New ELISA Kit Measures Chronic Kidney Disease Biomarker

By LabMedica International staff writers
Posted on 05 May 2015
Print article
Image: The FGF23 ELISA kit extends the existing line of Biomedica assays directed against chronic kidney disease (Photo courtesy of Biomedica Immunoassays).
Image: The FGF23 ELISA kit extends the existing line of Biomedica assays directed against chronic kidney disease (Photo courtesy of Biomedica Immunoassays).
A new ELISA kit has been released that is expected to become a valuable tool for researchers investigating new biomarkers that could improve prediction of chronic kidney disease (CKD) progression, as well as discovery of new drug targets.

The emergence of FGF23 as a potentially modifiable risk factor in CKD has led to growing interest in its measurement as a tool to assess patient risk and target therapy. In this regard, Biomedica Immunoassays (Vienna, Austria) has launched the first European CE marked FGF23 (C-terminal) ELISA assay that specifically detects both intact and C-terminal fragments of FGF23 in human serum and plasma. FGF23 (fibroblast growth factor 23) is a 32 kDa protein with 251 amino acids that is proteolytically processed between arginine179 and serine180 to generate N-terminal and C-terminal fragments. FGF23 is mainly secreted by osteocytes and controls phosphate and 1,25(OH)2 vitamin D homeostasis.

The kit comprises a sandwich enzyme immunoassay for the direct determination of FGF23 in human serum and plasma samples. In a first step, standards, samples, controls, and detection antibody (rabbit polyclonal anti-human FGF23-biotin) are dispensed into the wells of microtiter strips, which have been pre-coated with anti-FGF23 antibody. FGF23 present in the standards, samples, or controls binds to the pre-coated antibody in the well and forms a sandwich with the detection antibody. In the washing step all nonspecific unbound material is removed. In a second step, the conjugate (Streptavidin-horse radish peroxidase) is added to the wells and reacts with the detection antibody through avidin-biotin binding. After another washing step, the TMB (tetramethylbenzidine) substrate is dispensed into the wells. The enzyme catalyzed color change of the substrate is directly proportional to the amount of FGF23. This color change is detectable with a standard microtiter plate ELISA reader. A dose response curve of the absorbance (optical density at 450 nanometers) versus standard concentration is generated, using the values obtained from the standard. The concentration of FGF23 in the sample is determined directly from the dose response curve.

FGF23 is associated with cardiovascular and renal outcomes in patients with CKD and adds value to risk assessments based on conventional risk factors. “In particular, the ability to measure FGF23 in both serum and plasma samples and its stability in both matrices after sample collection opens up a significant new capability to learn about the mechanisms driving FGF 23 elevations in CKD,” said Dr. Wolfgang Woloszczuk, CSO of Biomedica Gruppe.


Related Links:
Biomedica Immunoassays

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.