We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Force-Sensing Microbots Designed to Probe Cells

By LabMedica International staff writers
Posted on 23 Oct 2014
Print article
Image: Side view of the microrobot next to a US penny (Photo courtesy of Purdue University).
Image: Side view of the microrobot next to a US penny (Photo courtesy of Purdue University).
Microrobots that have the capability of probing and engineering individual cells and tissue for biological research and medical applications are being constructed with technology that senses the minuscule forces exerted by a robot’s tiny probe.

Microrobots small enough to interact with cells already exist. However, there is no easy, inexpensive way to measure the small forces applied to cells by the robots. Measuring these microforces is vital to precisely control the bots and to use them to study cells. “What is needed is a useful tool biologists can use every day and at low cost,” said David Cappelleri, an assistant professor of mechanical engineering at Purdue University (West Lafayette, IN, USA).

Researchers now have devised and constructed a “vision-based micro-force sensor end-effector,” which is attached to the microrobots similar to a tiny proboscis. A camera is used to measure the probe’s displacement while it pushes against cells, allowing a simple calculation that reveals the force applied.

The new strategy could make it possible to easily measure the micronewtons of force applied at the cellular level. Such a tool is needed to better study cells and to understand how they interact with microforces. The forces can be used to convert cells into specific cell lines, including stem cells for research and medical applications. Moreover, the measurement of microforces can be used to examine how cells respond to specific drugs and to diagnose disease.

“You want a device that is low-cost, that can measure micronewton-level forces and that can be easily integrated into standard experimental test beds,” Dr. Cappelleri said. Microrobots used in research are controlled with magnetic fields to move them into place. “But this is the first one with a truly functional end effector to measure microforces,” he said.

The study’s findings were presented during the International Conference on Intelligent Robots and Systems, held in Chicago (IL, USA), September 14–18, 2014.

The new system is combined with the microrobot is about 700 micrometers square, and the researchers are working to create versions about 500 micrometers square. “We are currently working on scaling it down,” Dr. Cappelleri said.

Future research, according to the investigators, also may concentrate on automating the microrobots. The system was fabricated at the Birck Nanotechnology Center in Purdue’s Discovery Park.

Related Links:

Purdue University


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.