We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Siemens Healthineers - Laboratory Diagnostics

Provides advanced laboratory diagnostics solutions for the medical industry read more Featured Products: More products

Download Mobile App




Diabetic Kidney Disease and Risk of Incident Stroke Among T2D Adults

By LabMedica International staff writers
Posted on 08 Apr 2022

Atherosclerotic cardiovascular disease (ASCVD) is a significant cause of morbidity and mortality among people with type 2 diabetes (T2D) . More...

The huge burden of ASCVD in T2D, mainly coronary artery disease (CAD) and stroke, constitutes a major public health problem in this population and accounts for significant disability and healthcare costs.

Diabetes mellitus is associated with a 3-fold greater age-adjusted risk of stroke and a higher post-stroke mortality. The increased burden of stroke in individuals with T2D is driven in large part by the high prevalence of the metabolic syndrome components in this population. However, accruing evidence suggest that other factors such as diabetes-related microvascular complications might play a role. Indeed, diabetic retinopathy was found to be associated with higher risk of stroke in people with T2D.

A team of medical scientists collaborating with those at SOVAH Health (Danville, VA, USA) included in their study a total of 9,170 participants; mean age: 62.8 ± 6.6 years, 38.2% women, 62.9% white. Of the entire sample, 62.2% of participants had no chronic kidney disease (CKD); 13.3%, CKD G1; 14.1%, CKD G2; and 10.5%, CKD G3. Urine albumin-to-creatinine ratio (UACR) and estimated glomerular filtration rate (eGFR) were assessed at baseline.

Urine microalbumin was assayed on spot urine by immunonephelometry on a BN11 nephelometer (Siemens Healthineers, Erlangen, Germany). Urinary albumin excretion was estimated as the urine albumin-to-creatinine ratio (UACR) in mg albumin/g of creatinine. eGFR was calculated in mL/min/1.73 m2 using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula. Serum and urine creatinine was measured via enzymatic methods on a Roche Double Modular P Analytics automated analyzer (Roche Diagnostics, Indianapolis, IN , USA).

The scientists reported that over a median follow-up of 4.9 years, 156 participants developed a stroke (incidence rate 3.6/1,000 person-years). After adjusting for relevant confounders, higher UACR and lower eGFR were each associated with increased risk of stroke. Compared to UACR < 30 mg/g, moderate albuminuria and severe albuminuria were associated with increasing hazards for stroke (HR 1.61 and 2.29 respectively). Compared to eGFR of ≥ 60 mL/min/1.73 m2, decreased eGFR (eGFR < 60 mL/min/1.73 m2) was associated with higher risk of stroke (HR 1.50). Compared to no CKD, worsening CKD stage was associated with an increasing risk of stroke (HRs of 1.76 for CKD G1, 1.77 for CKD G2, and 2.03 for CKD G3).

The authors concluded that in a large and diverse cohort of adults with type 2 diabetes, higher UACR, decreased eGFR, and worsening CKD stages were associated with increased risk of stroke, independently of other stroke risk factors. The study was published on March 29, 2022 in the journal BMC Medicine.

Related Links:
SOVAH Health
Siemens Healthineers 
Roche Diagnostics 


New
Gold Member
Automated MALDI-TOF MS System
EXS 3000
Collection and Transport System
PurSafe Plus®
New
Gold Member
Hybrid Pipette
SWITCH
Automated Chemiluminescence Immunoassay Analyzer
MS-i3080
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: A schematic illustrating the coagulation cascade in vitro (Photo courtesy of Harris, N., 2024)

ADLM’s New Coagulation Testing Guidance to Improve Care for Patients on Blood Thinners

Direct oral anticoagulants (DOACs) are one of the most common types of blood thinners. Patients take them to prevent a host of complications that could arise from blood clotting, including stroke, deep... Read more

Microbiology

view channel
Image: EBP and EBP plus have received FDA 510(k) clearance and CE-IVDR Certification for use on the BD COR system (Photo courtesy of BD)

High-Throughput Enteric Panels Detect Multiple GI Bacterial Infections from Single Stool Swab Sample

Gastrointestinal (GI) infections are among the most common causes of illness worldwide, leading to over 1.7 million deaths annually and placing a heavy burden on healthcare systems. Conventional diagnostic... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.