We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Lynch Syndrome Screening by IHC Leads to Mutation Studies

By LabMedica International staff writers
Posted on 24 Oct 2019
Lynch syndrome or hereditary nonpolyposis colorectal cancer is an autosomal dominant genetic condition that is associated with a high risk of colon cancer, as well as other cancers including endometrial cancer, ovary, stomach, small intestine, hepatobiliary tract, upper urinary tract, brain, and skin.

Immunohistochemical expression of mismatch repair (MMR) protein is a well-accepted method for routine screening for Lynch syndrome (LS) with relatively high sensitivity and specificity. More...
Occasionally, however, immunohistochemistry (IHC) can yield an equivocal result with poor reproducibility and the potential for misdiagnosis.

A pathologist and a geneticist from the University of Texas Southwestern Medical Center (Dallas, TX, USA) retrospectively analyzed the data on MMR (MLH1, PMS2, MSH2, and MSH6) IHC results from their database of 479 patients with colorectal cancer (CRC) and endometrial cancer (EC) who were screened for LS between September 2011 and August 2013. Mismatch repair protein IHC was performed prospectively in all patients with a tissue diagnosis of CRC or EC before 70 and 50 years of age, respectively.

Semi-quantitative scoring of MMR IHC was performed by image analysis in 479 cases, of which 380 were colorectal and 99 endometrial cancers. Scores of 10% or more, less than 10%, and 0% were used as cutoffs for retained, indeterminate, and loss of expression, respectively. Negative and indeterminate IHC results were confirmed by mutational studies. The automated cell imaging system consisted of an automated robotic bright-field microscope module and a Windows NT–based software interface that digitizes the IHC-stained slide, and digital images were displayed on a computer screen and analyzed by proprietary software. Confirmatory germline testing was initiated after counseling the patients about the abnormal IHC results and obtaining their permission for further genetic testing.

The scientists reported that 418/479 cases (87.2%) were reported as retained expression, 45 (9.3%) as loss of expression, and 16 (3.3%) as indeterminate expression. Fifteen of 45 (33.3%) and eight of 16 (50%) with loss and indeterminate expression, respectively, were found to have Lynch syndrome by germline studies. The overall frequency of Lynch syndrome in the patient population was 4.8% (23/479), and 34.7% of these (8/23) were associated with indeterminate IHC expression. In the indeterminate group, MLH1 germline mutation was the most frequent (6/13; 46.2%), followed by MSH6 (4/13; 30.7%).

The authors concluded that their findings provided further evidence that indeterminate IHC should be further investigated for possible MMR germline mutation. Guidelines for interpretation of MMR IHC and the establishment of more objective criteria for defining indeterminate results are important to improve the sensitivity and specificity of the IHC assay. The study was published in the October 2019 issue of the journal Archives of Pathology and Laboratory Medicine.

Related Links:
University of Texas Southwestern Medical Center


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
New
Nucleic Acid Purification Instrument
QIAsymphony Connect
Gold Member
Neonatal Heel Incision Device
Tenderfoot
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The automated multiplex PCR assay runs on the BioFire Spotfire Vaginitis System, bringing molecular vaginitis testing to the point of care (Photo courtesy of bioMérieux)

Molecular Vaginitis Panel Gains FDA Clearance and CLIA Waiver for Point-of-Care Use

Vaginitis affects most women at least once in their lifetime and can cause painful, disruptive symptoms. Common causes include bacterial vaginosis, vulvovaginal candidiasis, and trichomoniasis, reflecting... Read more

Immunology

view channel
Image Credit: iStock

Antibody Profiling Predicts Inflammatory Bowel Disease Years Before Diagnosis

Inflammatory bowel disease (IBD), which includes Crohn’s disease and ulcerative colitis, involves abnormal immune responses that cause persistent inflammation and damage in the digestive system.... Read more

Technology

view channel
Image: Signals LabGistics uses AI to turn natural-language instructions and SOPs into coordinated scientific workflows, helping connect teams, systems, and processes. (Photo courtesy of Revvity)

New AI-Powered System Aims to Streamline Laboratory and Manufacturing Workflows

Scientific laboratories supporting drug development, biotechnology, and materials research increasingly rely on coordinated digital workflows to move data, samples, and activities across teams.... Read more

Industry

view channel
Image: The integration with FlexLab X brings the Panther System into fully tracked automation environments to increase capacity, traceability, and workflow efficiency (Photo courtesy of Hologic)

Hologic and Inpeco Partner to Advance Molecular Laboratory Automation in Europe

Hologic, Inc. (Marlborough, MA, USA) and Inpeco S.A. (Novazzano, Switzerland) have signed a co-marketing partnership in Europe for Inpeco’s recently launched FlexLab X automation solution and Hologic’s... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.