Magneto-Optical Diagnosis Evaluated for Symptomatic Malaria

By LabMedica International staff writers
Posted on 02 Mar 2021
Print article
Image: Malaria: Thick bloods smear showing ring-form trophozoites of Plasmodium vivax that are difficult to detect. Two ring-forms are arrowed (Photo courtesy of US Centers of Diseases Control and Prevention).
Image: Malaria: Thick bloods smear showing ring-form trophozoites of Plasmodium vivax that are difficult to detect. Two ring-forms are arrowed (Photo courtesy of US Centers of Diseases Control and Prevention).
Malaria places a significant social and economic burden on many tropical developing countries, further undermining the potential for growth. Development of rapid, easy-to-use and low-cost malaria diagnostic methods, with high sensitivity and specificity, remains an urgent priority for tropical diseases.

Currently available methods to diagnose malaria include the inspection of blood smears using light microscopy (LM), rapid diagnostic tests (RDTs), and molecular methods, such as polymerase chain reaction (PCR) or other molecular techniques. A novel method, named rotating-crystal magneto-optical detection has been evaluated.

An international team of scientists led by those at the James Cook University (Smithfield, Australia) developed and tested the method called rotating-crystal magneto-optical detection (RMOD) on nearly 1,000 suspected malaria patients in a high-transmission area of Papua New Guinea. The novel method was compared with LM, using thick blood smears for parasite density quantification and real time PCR that employed a two-step protocol using a using a CFX96 Touch qPCR system (Bio-Rad Laboratories Pty., Ltd., Gladesville, Australia).

The team reported that compared to light microscopy, RMOD exhibits 82% sensitivity and 84% specificity to detect any malaria infection and 87% sensitivity and 88% specificity to detect Plasmodium vivax. This indicates that RMOD could be useful in P. vivax dominated elimination settings. Parasite density correlates well with the quantitative magneto-optical signal. Importantly, residual hemozoin present in malaria-negative patients is also detectable by RMOD, indicating its ability to detect previous infections.

Stephan Karl, PhD, a Senior Research Fellow and a corresponding author of the study, said, “Malaria is easily treated but it is actually hard to diagnose, and because of that there can be over-treatment, which we have seen can lead to the spread of drug-resistant malaria. Malaria parasites break down blood in such a way that heme molecules in the blood assemble themselves into organic crystallites containing magnetic iron, which is detected by the RMOD method.”

The authors concluded that they had carried out an extensive assessment of a promising novel method to diagnose malaria rapidly and at low cost in a high transmission setting and a population of symptomatic, suspected malaria cases in Papua New Guinea. The present study shows that in such a setting, the RMOD performs well in comparison to expert LM-based diagnosis, the most reliable reference method in their study. The study was published on February 12, 2021 in the journal Nature Communications.

Related Links:
James Cook University
Bio-Rad Laboratories


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Cancer Mutation Profiling Liquid Kit
OncoScreen Plus

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: The study showed the blood-based cancer screening test detects 83% of people with colorectal cancer with specificity of 90% (Photo courtesy of Guardant Health)

Blood Test Shows 83% Accuracy for Detecting Colorectal Cancer

Colorectal cancer is the second biggest cause of cancer deaths among adults in the U.S., with forecasts suggesting 53,010 people might die from it in 2024. While fewer older adults are dying from this... Read more

Hematology

view channel
Image: The Gazelle Hb Variant Test (Photo courtesy of Hemex Health)

First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy

Hemoglobin disorders rank as some of the most prevalent monogenic diseases globally. Among various hemoglobin disorders, beta thalassemia, a hereditary blood disorder, affects about 1.5% of the world's... Read more

Industry

view channel
Image: These new assays are being developed for use on the recently introduced DxI 9000 Immunoassay Analyzer (Photo courtesy of Beckman Coulter)

Beckman Coulter and Fujirebio Expand Partnership on Neurodegenerative Disease Diagnostics

Beckman Coulter Diagnostics (Brea, CA, USA) and Fujirebio Diagnostics (Tokyo, Japan) have expanded their partnership focused on the development, manufacturing and clinical adoption of neurodegenerative... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.