Point-of-Care Capillary Whole Blood Hematocrit and Hemoglobin Compared

By LabMedica International staff writers
Posted on 14 Jun 2015
The clinical suitability of point-of-care devices for conductivity based point-of-care hematocrit with calculated hemoglobin necessitates that they be accurate and that the results are interchangeable with central laboratory methods.

The appropriateness of conductivity based assays in certain patient populations, such as patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions, has been questioned. More...


Clinical laboratory scientists at Massachusetts General Hospital (Boston, MA, USA) performed hematocrit and hemoglobin analysis on 225 clinical samples obtained from intensive care units and the cardiac surgery operating room. All samples were from adult patients over 18 years of age. The samples were first tested for clinical care and then immediately handed off to technologists for the study testing.

The total hemoglobin level was first measured by co-oximetry on the Siemens RAPIDLab 1265 analyzer (Siemens Medical Solutions USA, Inc.; Malvern, PA, USA). Hematocrit and hemoglobin values were obtained on the Abbott i-STAT instrument using one lot of i-STAT E3+ cartridges (Abbott Point of Care; Princeton, NJ, USA). Hemoglobin values from the i-STAT are performed by the calculation of directly measured hematocrit in percent × 0.34. A manual spun hematocrit was performed on each sample as the standard hematocrit reference method. The hematocrit and hemoglobin were also determined on the automated hematology analyzer XE5000 (Sysmex Corporation; Kobe, Japan) by impedance based cumulative pulse height detection and by photometric determination, respectively.

The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method or the Sysmex photometric hemoglobin method. The results on the i-STAT were statistically significantly different from those obtained on the Sysmex for hematocrit and the Siemens RAPIDLab co-oximeter for hemoglobin.

The authors concluded that the i-STAT hematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. The study was published in the June 2015 issue of the journal Clinica Chimica Acta.

Related Links:

Massachusetts General Hospital 
Siemens Medical Solutions USA 
Abbott Point of Care 



New
Gold Member
Quality Control Material
iPLEX Pro Exome QC Panel
3-Part Differential Hematology Analyzer
Swelab Alfa Plus Sampler
New
Silver Member
Quality Control Material
NATtrol Chlamydia trachomatis Positive Control
New
Drug Test Kit
DrugCheck 3000
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








DIASOURCE (A Biovendor Company)

Channels

Molecular Diagnostics

view channel
Image: The RNA-seq based diagnostic test for pediatric leukemia ensures better outcomes for children with this common cancer (Photo courtesy of Qlucore)

RNA-Seq Based Diagnostic Test Enhances Diagnostic Accuracy of Pediatric Leukemia

A new unique test is set to reshape the way Acute Lymphoblastic Leukemia (BCP-ALL) samples can be analyzed. Qlucore (Lund, Sweden) has launched the first CE-marked RNA-seq based diagnostic test for pediatric... Read more

Immunology

view channel
Image: A simple blood test could replace surgical biopsies for early detecion of heart transplant rejection (Photo courtesy of Shutterstock)

Blood Test Detects Organ Rejection in Heart Transplant Patients

Following a heart transplant, patients are required to undergo surgical biopsies so that physicians can assess the possibility of organ rejection. Rejection happens when the recipient’s immune system identifies... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.