New Serological Assay Uses Optical Biosensor to Measure Antibody Levels in Blood Samples within 20 Minutes

By LabMedica International staff writers
Posted on 17 Dec 2020
Print article
Image: Rebecca Dubois in her lab at UC Santa Cruz. (Photo courtesy of C. Laguttuta)
Image: Rebecca Dubois in her lab at UC Santa Cruz. (Photo courtesy of C. Laguttuta)
Researchers have developed a novel serological assay that uses optical biosensor technology to provide quantitative measurements of antibodies in blood plasma in less than 20 minutes.

The new method developed by researchers at UC Santa Cruz (Santa Cruz, CA, USA) is as accurate as the most reliable antibody tests currently available, but is less complex and can be performed much faster.

The new method, called biolayer interferometry immunosorbent assay (BLI-ISA), provides complete quantitative results in less than 20 minutes. The new BLI-ISA method uses biolayer interferometry, an optical technique for measuring the interactions between molecules by detecting the binding of molecules to the tip of a fiber-optic biosensor. The instruments required to perform biolayer interferometry are increasingly common in research laboratories.

The new serological assay involves several steps performed by the instrument in an automated “dip-and-read” format. In the first step, the biosensor tip is dipped into a solution containing the antigen (a viral protein) that is recognized by the antibody to be tested for. As the antigen binds to the biosensor tip, it generates a signal that can be used for quality control to ensure consistency in the antigen loading step. Next, after dipping into a wash solution, the biosensor is dipped into the blood plasma sample, generating a signal as antibodies bind to the antigen.

The immune system makes different types of antibodies, called isotypes, including IgM, which is produced early in the infection and declines later, and IgG, which is produced later and persists longer. In the antibody binding step, the BLI instrument detects any type of antibody that binds to the antigen. The next step detects and quantifies IgG antibodies specifically by measuring the binding of anti-IgG antibodies. The assay thereby provides quantitative measurements of both total antibodies and IgG antibodies, and it can be designed to measure different isotypes as well.

The researchers developed and tested the new assay using RBD antigens, although it can be used to detect a wide range of antigens. The BLI instrument allows easy “multiplexing,” meaning that multiple tests can be run in parallel on the same blood sample to detect antibodies to different viral antigens as well as different antibody isotypes. Because it requires laboratory equipment, BLI-ISA could not be used as a point-of-care test at doctor’s offices or pharmacies. However, it allows high-throughput processing of samples and is faster and less labor intensive than other quantitative laboratory tests such as ELISA, Immunofluorescent Assay, and Chemiluminescent Immunoassay. The amount of blood needed for the test can be obtained with a finger prick.

Another advantage of BLI-ISA over other methods is the ease of standardizing the assay so that a sample gives the same quantitative results in repeated tests at different times or in different laboratories. ELISA requires an enzyme-based signal amplification step, which can vary depending on temperature and other factors, resulting in much more test-to-test variability in the quantitative measurements. The researchers believe that the new assay could be especially useful for researchers in vaccine development.

“Our assay is as sensitive if not better than other assays in detecting low levels of antibodies, and the specificity [false-positive rate] is as good as the best antibody tests out there,” said Rebecca DuBois, associate professor of biomolecular engineering at UC Santa Cruz. “It combines the advantages of the test strips that take 20 minutes with the quantitative results and higher performance of ELISA.”

“This method provides a standardized way to quantify antibody levels, which could be used to compare antibody responses to different vaccine candidates,” said first author John Dzimianski, a postdoctoral researcher in DuBois’s lab. “In addition, running the assay itself is straightforward, requiring little more than the push of a button. It’s a simple but powerful tool.”

Related Links:
UC Santa Cruz

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
COVID-19 Rapid Test
AQ+ COVID-19 Ag Rapid Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.