Novel Presepsin Assay Evaluated Using Automated Immunoanalyzer

By LabMedica International staff writers
Posted on 27 Jul 2022
Print article
Image: The HISCL Presepsin Assay Kit can be used with its Automated Immunoassay System HISCL-5000/2000i/800 for immunochemistry testing (Photo courtesy of Sysmex Corporation)
Image: The HISCL Presepsin Assay Kit can be used with its Automated Immunoassay System HISCL-5000/2000i/800 for immunochemistry testing (Photo courtesy of Sysmex Corporation)

Biomarkers that reflect systemic responses during sepsis have been studied continuously, and there are various surrogate markers for the diagnosis of sepsis. Procalcitonin (PCT), C-reactive protein (CRP), cytokines, and chemokines have been studied extensively under the previous and revised sepsis definitions.

A soluble CD14 molecule (presepsin) has been developed and applied toward the diagnosis and prognosis of sepsis. Presepsin is a soluble CD14 molecule that is cleaved and released into the general circulation after activation by a monocyte or macrophage. Pathogen-associated molecular species such as lipopolysaccharide (LPS) from gram-negative bacteria can bind to serum lipoprotein-binding protein, both of which bind to CD14.

Biomedical Scientists at the Seoul St. Mary's Hospital, College of Medicine (Seoul, South Korea) collected samples from sepsis patients visiting the emergency department were collected before a treatment. Sepsis was diagnosed using a SOFA score with suspected bacterial infection. Reference intervals were analyzed and 124 subjects without underlying disease or prescribed medication from electronic medical records were selected.

For method comparison, 87 samples from suspected sepsis patients were collected within 24 hours from blood drawn and refrigerated at −80 °C for method comparison in duplicate. A total of 84 plasma from EDTA samples was analyzed with the chemiluminescence enzyme immunoassay by both Sysmex HISCL-5000 (Sysmex Corporation, Kobe, Japan) and PATHFAST (LSI Medience Corporation, Tokyo, Japan). For Sysmex HISCL-5000, the measurement range was from 0 to 30,000 pg/mL and for PATHFAST, the measurement range was from 0 to 20,000 pg/mL. Precision, linearity, limit of blank/limit of detection, method comparisons, and reference intervals were evaluated.

The investigators reported that precision using a 20×2×2 protocol for low (306 pg/mL) and high (1,031 pg/mL) levels resulted in within-laboratory standard deviation (95% confidence interval [CI]) and coefficient of variation (CV) %, which were as follows: 15.3 (13.1–18.7), 5.5% and 47.7, (40.5–58.1), 6.4%, respectively. Linearity using patient samples and calibrators were measured from 201 to 16,177 and 188 to 30,000 pg/mL, respectively. The correlation coefficient (95% CI) was 0.869 (0.772–0.927) with statistical significance. Reference intervals from 120 normal healthy subjects showed that 300 pg/mL was the cut off. Presepsin tended to show a higher value at higher ages and in males. A method comparison between Sysmex HISCL-5000 and PATHFAST was performed and the correlation coefficient was 0.979, which showed a high correlation coefficient.

The authors concluded that presepsin analyzed by HISCL-5000 showed reliable analytical performance that could be used in clinical settings. A wide range of analytical measurements ranging from 200 to 30,000 pg/mL was verified. As presepsin showed positive and negative correlations with hematocrit and renal function, careful interpretation is required for patients with underlying diseases involving red blood cells or kidneys. The study was published on July 23 2022 in the Journal of Clinical Laboratory Analysis.

Related Links:
Seoul St. Mary's Hospital, College of Medicine 
Sysmex Corporation 
LSI Medience Corporation 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.