HbA1c Assessed in Diabetics Awaiting Liver Transplantation

By LabMedica International staff writers
Posted on 31 Dec 2018
Print article
Image: Glycated hemoglobin (HbA1c) as an indicator of diabetes (Photo courtesy of Diabetes.co.uk).
Image: Glycated hemoglobin (HbA1c) as an indicator of diabetes (Photo courtesy of Diabetes.co.uk).
A glycated hemoglobin (HbA1c) test measures the amount of blood sugar (glucose) attached to hemoglobin. An HbA1c test shows what the average amount of glucose attached to hemoglobin has been over the past three months. It's a three-month average because that's typically how long a red blood cell lives.

Diabetes is a leading cause of liver disease, with cirrhosis responsible for a considerable number of deaths in people with diabetes. The relationship between HbA1c and glucose in people with co-existing liver disease and diabetes awaiting transplant, and in those with diabetes but no liver disease has been investigated.

Scientists collaborating with the University of Birmingham (Birmingham, UK) collected HbA1c and random plasma glucose data for 125 people with diabetes without liver disease and for 29 people awaiting liver transplant with diabetes and cirrhosis. The median (interquartile range) Model for End Stage Liver Disease score for the study cohort was calculated as 12 (9-17; normal is less than 6). In those with cirrhosis, this was caused by non-alcoholic fatty liver disease, hepatitis C, alcoholic liver disease, hereditary hemochromatosis, polycystic liver/kidneys, cryptogenic/non-cirrhotic portal hypertension and α-1-antitrypsin-related disease.

The team found that the median (interquartile range) HbA1c concentrations were 41 (32-56) mmol/mol [5.9 (5.1-7.3)]% versus 61 (52-70) mmol/mol [7.7 (6.9-8.6)%], respectively, in the diabetes with cirrhosis group versus the diabetes without cirrhosis group and the glucose concentrations were 8.4 (7.0-11.2) mmol/L versus 7.3 (5.2-11.5) mmol/L. HbA1c concentration was depressed by 20 mmol/mol (1.8%) in 28 participants with cirrhosis, but elevated by 28 mmol/mol (2.6%) in the participant with α-1-antitrypsin disorder.

Those with cirrhosis and depressed HbA1c concentrations had fewer larger erythrocytes, and higher red cell distribution width and reticulocyte count. This was reflected in the positive association of glucose with mean cell volume and hemoglobin level and the negative association for HbA1c concentration in the diabetes group. The authors concluded that HbA1c is not an appropriate test for blood glucose in people with cirrhosis and diabetes awaiting transplant as it reflects altered erythrocyte presentation. The study was published on November 26, 2018, in the journal Diabetic Medicine.

Related Links:
University of Birmingham

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.