We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Experimental Drug Brings Remission in Eighty Percent of Melanoma Patients

By LabMedica International staff writers
Posted on 08 Sep 2010
Results obtained in a multicenter clinical study have revealed that treatment of metastatic melanoma with the experimental oral drug PLX4032 (RG7204) in patients with tumors that carry the V600E BRAF mutation resulted in complete or partial tumor regression in nearly 80% of patients.

The protein encoded by the BRAF gene plays a role in regulating the MAP kinase/ERKs signaling pathway, which affects cell division, differentiation, and secretion. More...
Mutations in this gene have been associated with various cancers, including non-Hodgkin lymphoma, colorectal cancer, malignant melanoma, thyroid carcinoma, non-small-cell lung carcinoma, and lung adenocarcinoma. The drug PLX4032 is a potent inhibitor of proliferation of the ERK pathway in melanoma cell lines expressing the BRAF-V600E mutation (at amino acid position number 600 on the BRAF protein, the normal valine is replaced by glutamic acid). About 60% of melanomas have the V600E mutation.

In the current study, researchers at Memorial Sloan-Kettering Cancer Center (New York, NY, USA) and their colleagues conducted a multicenter phase 1 dose-escalation trial of PLX4032 followed by an extension phase involving the maximum dose that could be administered without adverse effects (the recommended phase 2 dose). Patients received PLX4032 twice daily until they had disease progression. Pharmacokinetic analysis and tumor-response assessments were conducted in all patients. In selected patients, tumor biopsy was performed before and during treatment to validate BRAF inhibition.

Results published in the August 26, 2010, issue of the New England Journal of Medicine (NEJM) revealed that in the dose-escalation cohort, among the 16 patients with melanoma whose tumors carried the V600E BRAF mutation and who were receiving 240 mg or more of PLX4032 twice daily, 10 had a partial response and one had a complete response. Among the 32 patients in the extension cohort, 24 had a partial response and two had a complete response. The estimated median progression-free survival among all patients was more than seven months. The side effects of PLX4032 were relatively minor and included rash, nausea, photosensitivity, fatigue, and the formation of benign squamous cell skin tumors.

"We have never seen an 80% response rate in melanoma, or in any other solid tumor for that matter, so this is remarkable,” said senior author Dr. Paul Chapman, senior researcher in the melanoma and sarcoma service at the Memorial Sloan-Kettering Cancer Center. "The tumor responses induced by PLX4032 are not always long-lasting though, and we do not know if treatment really improves overall survival of melanoma patients. That is what we are trying to find out in the ongoing phase III trial. In the future, we hope to combine PLX4032 with other anti-melanoma drugs currently being developed.”

"Metastatic melanoma is a very challenging disease to treat and there have been no significant therapeutic advances in the past 20 years. What has changed is that we learned that half of melanomas are addicted to a mutated gene called BRAF; this new, targeted drug inhibits BRAF and shuts off these tumors. We have seen many tumors shrink rapidly and, in some patients, quality of life improved dramatically,” said Dr. Chapman. "This is the beginning of personalized medicine in melanoma.”

Related Links:
Memorial Sloan-Kettering Cancer Center



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
POC Immunoassay Analyzer
Procise DX
Gold Member
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Microbiology

view channel
Image: Schematic overview of the CRISPR-Assisted Nanodroplet-pairing Platform for Differential Identification of NTM (CANDI). The platform combines broad-range amplification using conserved regions of the 16S and 23S rRNA genes with species-specific CRISPR recognition. Fluorescence-coded CRISPR droplets are paired with sample droplets containing amplified products, enabling multiplexed target recognition and signal decoding (Image Credit: Yiwen Yang, Jingsong Xu, Dakang Xu)

Nanodroplet CRISPR Technology Supports Rapid, Multiplexed Mycobacterial Identification

Mycobacterial infections are difficult to diagnose because closely related species can have different clinical and therapeutic implications. Nontuberculous mycobacteria (NTM) are increasingly recognized... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image: TruVerus is designed to deliver a broad menu of routine blood tests from a small blood sample on a single, automated benchtop platform (Photo courtesy of Truvian Health)

Collaboration Advances Automated Benchtop Platform for Routine Blood Testing

Routine blood testing is central to clinical decision-making, but access can vary across laboratory and healthcare settings. Broader use of automated benchtop platforms may help integrate testing more... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.