Amplification Tests Evaluated for Pelvic Inflammatory Disease

By LabMedica International staff writers
Posted on 23 Jan 2018
Print article
Sexually transmitted Chlamydia trachomatis (chlamydia) is the most prevalent sexually transmitted infection (STI) with an estimated 68,455,000 incident cases globally in women in 2012. Chlamydia is the subject of intensive control efforts in many high-income settings.

Nucleic Acid Amplification Tests (NAATs) are the recommended test type for diagnosing C. trachomatis; however, less sensitive diagnostic methods, including direct immunofluorescence (IF) and enzyme-linked immunoassay (ELISA), remain in use in lower resourced settings.

Danish and British scientists led by those at the Imperial College London (London, UK) extracted from the Denmark’s national Chlamydia Study dataset all chlamydia test records from women aged 15 to 34 years that were performed between January 1, 1998 and December 31, 2001, the interval when non-NAATs were replaced by NAATs as the most common test type. Tests were categorized as non-NAAT (IF/ELISA) or NAAT and limited to each woman’s first test in the study period. They linked test data to hospital presentations for pelvic inflammatory disease (PID) within 12 months.

The study included 272,105 women with a chlamydia test, just under half (44.78%) were tested using NAATs. Overall, 17,353 (6.38%) tested positive for chlamydia and 1,732 (0.64%) were diagnosed with PID within 12 months. The risk of PID following a positive chlamydia test did not differ by test type (NAAT 0.81%, non-NAAT 0.78%). The risk of PID following a negative test was significantly lower in women tested with NAATs compared to non-NAATs (0.55% compared to 0.69%). The team estimated that 18% of chlamydia infections in women tested with a non-NAAT were undiagnosed and that the risk of progression from undiagnosed chlamydia infection to PID within 12 months was 9.52%. The use of non-NAATs could lead to an excess of 120 cases of PID per 100,000 women tested compared to using NAATs.

The authors concluded that their retrospective observational study estimates the positive impact on women’s reproductive health from using accurate chlamydia diagnostic tests and provides further evidence for restricting the use of inferior tests. Women with a negative chlamydia test have a 17% higher adjusted risk of PID by 12 months if they are tested using a non-NAAT compared to a NAAT. The study was published on January 2, 2018, in the journal Public Library of Science Medicine.

Related Links:
Imperial College London

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing