We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Thromboelastometry Analysis Assessed for Thrombocytopenic Dengue Patients

By LabMedica International staff writers
Posted on 01 Feb 2017
Print article
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Image: The rotational thromboelastometry (ROTEM) delta hemostasis analyzer measures kinetic changes of the clot elasticity of whole blood samples (Photo courtesy of ROTEM).
Dengue virus infection (DVI) is a prevalent and potentially fatal viral disease associated with coagulopathy. Dengue hemorrhagic fever (DHF) represents a severe clinical presentation of DVI and is characterized by the presence of varying degrees of hemostatic disorders.

Rotational thromboelastometry is a point of care test that promptly provides within 5 to 30 minutes information about the dynamics of clot formation, stabilization and dissolution, reflecting the in vivo hemostasis at the bedside.

Physicians at the Hospital Israelita Albert Einstein conducted a cross-sectional study during a DVI outbreak in São Paulo, Brazil, between April 6 and May 5, 2015. Patients with at least 24 hours of fever (axillary temperature greater than 37.8 °C), in addition to a positive dengue virus (DV) specific immunoglobulin IgM/IgG or non-structural protein-1 (NS1) antigen rapid test and platelet count less than 100 × 109/L were consecutively included in this study.

Rotational Thromboelastometry and the conventional coagulation tests prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), thrombin time (TT), platelet count and fibrinogen levels were performed in 53 patients with DVI and thrombocytopenia. Measurement of coagulation in ROTEM was performed after the vertical immersion of a plastic pin into the blood sample. The pin rotates slowly backwards and forwards through an angle of 4.75°. By generation of the first fibrin filaments between the pin and the wall of the test cup, the rotational range of the pin is reduced. The increased restriction of the pin’s movement is transferred to a graphical display, a plot that shows changes in the viscoelastic properties of the clot over time.

The team found that despite a median interquartile range (IQR) platelet count of 77 (63–88) × 109/L in DVI patients, conventional coagulation tests and plasma fibrinogen levels were within the normal range. Subjects demonstrated hypercoagulability in 71.7% (38/53) in intrinsically activated thromboelastometry test (INTEM) and 54.7% (29/53) in extrinsically activated thromboelastometry test (EXTEM) in DVI patients. Fibrin-based thromboelastometry test (FIBTEM) analyses detected only 5.7% (3/53) with hypocoagulability among this population. The median (IQR) clotting time (CT), clot formation time (CFT) and maximum clot firmness (MCF) on INTEM were, respectively, 177 (160–207) seconds, 144 (108–178) seconds and 48 (42–52) mm. On EXTEM, median (IQR) CT, CFT and MCF were, respectively, 69 (65–78) seconds, 148 (126–198) seconds and 49 (44–55) mm.

The authors concluded that thromboelastometry impairment is highly prevalent in DVI patients with thrombocytopenia, particularly in INTEM and EXTEM analyses, while standard coagulation tests are normal in this setting, but clinical implications remain to be established. The study was published on January 19, 2017, in the journal BMC Infectious Diseases.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.