We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

TAIGEN BIOSCIENCE CORP

Taigen Bioscience Corporation develops, manufactures, and sells nucleic acid extraction reagents, fully automated ins... read more Featured Products: More products

Download Mobile App




Commercial Molecular Assay Validated for Dengue Virus Outbreak

By LabMedica International staff writers
Posted on 28 Oct 2016
Print article
Image: The LabTurbo 48 compact system can fully automate DNA/RNA extraction of up to 48 samples in 90 minutes (Photo courtesy of Taigen Bioscience).
Image: The LabTurbo 48 compact system can fully automate DNA/RNA extraction of up to 48 samples in 90 minutes (Photo courtesy of Taigen Bioscience).
Dengue virus (DENV) is a member of the viral genus Flavivirus (family Flaviviridae) that is transmitted by mosquitos, causing endemic and epidemic outbreaks in tropical and subtropical areas.

Accurate, rapid, and early diagnosis of DENV infections is important for public health and optimal clinical care; however, the gold standard method of cell culture-dependent isolation of DENV during the acute phase of infection is time-consuming and cumbersome.

Medical scientists at the National Cheng Kung University (Tainan, Taiwan) collected serum samples from patients with suspected DENV infection between July and November 2015. Sera from patients with suspected DENV infection were screened using the one-step immunochromatographic SD BIOLINE Dengue DuoDengue NS1 Ag + Ab Combo assay. This rapid assay contains two test devices, which can simultaneously detect the levels of nonstructural protein 1(NS1) antigen, and immunoglobulin M (IgM) and IgG in a sample, respectively, within 15 minutes.

Viral ribonucleic acid (RNA) was extracted from serum samples and an extraction control sample using a QAIamp viral RNA mini kit or the automated extraction system LabTurbo Virus mini Kit in LabTurbo 48 Compact System. Quantitative real-time polymerase chain reaction (qRT-PCR) analysis of viral loads was performed using LightMix dengue virus EC kit, which is capable of identifying all four dengue serotypes.

A total of 8,989, 8,954, and 1,581 samples were subjected to NS1 antigen detection, IgM and IgG detection, and LightMix assays, respectively. The LightMix assay yielded a linear curve for viral loads (VL) between 102 and 106 copies/reaction, and the minimum detection limits for DENV serotype 1 (DENV1) and DENV2, DENV3, and DENV4 were 1, 10, and 100 focus forming units (FFU)/mL, respectively. There was 88.9% concordance between the results obtained using the NS1 antigen combo kit and by LightMix analysis, and the diagnostic sensitivity and specificity of the two methods were 89.4% and 100%, and 84.7% and 100%, respectively.

The authors concluded that the LightMix assay was effective for early diagnosis of DENV infection. The data indicated that high viral loads during primary infection in elderly patients may be a positive predictor for severe illness, and may contribute to high mortality rates. The study was published on October 12, 2016, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:
National Cheng Kung University


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.