Rapid Ebola Virus Detection Assay Evaluated

By LabMedica International staff writers
Posted on 17 Nov 2015
Print article
Image: The Diagnostics-in-a-Suitcase used to screen for Ebolavirus disease (Photo courtesy of Institut Pasteur, Dakar).
Image: The Diagnostics-in-a-Suitcase used to screen for Ebolavirus disease (Photo courtesy of Institut Pasteur, Dakar).
Ebolavirus (EBOV) infection is mainly diagnosed by various in-house and commercial real-time reverse transcriptase polymerase chain reaction (RT-PCR) assays used in up to 38 laboratories implemented at or close to Ebola treatment centers (ETC) in West Africa.

Transmission of Ebolavirus disease (EVD) occurs almost exclusively from human to human by direct contact with body fluids of symptomatic cases. Consequently, the control strategy for EVD epidemics relies on early identification of EBOV-infected patients and corpses for, respectively, isolation and safe burials.

An international team of scientists led by those at the Institut Pasteur de Dakar (Dakar, Senegal) evaluated a new nucleic acid extraction kit on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebolavirus (EBOV-RT-RPA) that was compared in parallel to other methods. Serum samples from acute cases and cheek and tongue swabs from deceased were collected. In addition, following an upsurge of EVD cases connected to funeral rites, oral swabs from all deceased were tested at the morgue.

The extraction kit tested was the SpeedXtract Nucleic Acid Kit (SE), (Qiagen; Hilden, Germany). The W-PCR was performed on the SmartCycler (Cepheid; Sunnyvale, CA, USA) using the RNA Master Hybridisation Probes kit (Roche; Manheim, Germany). A mobile laboratory was used which consisted of a glovebox, a Diagnostics-in-a-Suitcase (DiaS), and a solar panel and power pack set. The RT-RPA was performed using a custom-made EBOV-specific exo RT kit with pellets containing optimized enzyme concentrations.

The EBOV-RT-RPA was evaluated in comparison to two real-time PCR assays. The prevalence of EBOV in the swabs tested was 12.9%. The day of death after onset of disease peaked at day 6 (range: 2 to14 days) in the group of 67 swab-positive deceased for whom disease symptoms were recorded. Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 minutes, and the field deployment of the mobile laboratory helped improve burial management and community engagement.

Related Links:

Institut Pasteur de Dakar  
Qiagen
Cepheid


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.