We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

Download Mobile App




Rapid Test Kit Detects Dengue Antibodies in Saliva

By LabMedica International staff writers
Posted on 09 Feb 2015
Print article
Image: A three dimensional model of the rapid test kit that detects dengue-specific antibodies (Photo courtesy of the Agency for Science, Technology and Research, A*STAR).
Image: A three dimensional model of the rapid test kit that detects dengue-specific antibodies (Photo courtesy of the Agency for Science, Technology and Research, A*STAR).
A paper-based disposable device has been developed that will allow dengue-specific antibodies to be detected easily from saliva within 20 minutes and the device is currently undergoing further development.

Paper-based immunoassays, usually in the form of lateral flow tests, are currently the standard platform for home diagnostics. However, conventional lateral tests are often complicated by severe nonspecific adsorption of detector particles when applied to test samples containing salivary fluid.

Scientists at the Institute of Bioengineering and Nanotechnology (The Nanos; Singapore) developed a stacking flow device consisting of a test strip, a sample pad, a reagent pad, an absorbent pad, and a flow regulator. The sample and reagent pads were made of glass fiber, and the absorbent pad was made of cellulose (Merck Millipore, Billerica, Massachusetts, USA). The nitrocellulose test strip was cut into the required dimensions manually with a roller cutter. The detection of dengue-specific immunoglobulin G (IgG) was conducted using the liquid conjugate approach. The liquid conjugate was composed of protein G-conjugated 40 nm gold nanoparticles.

In the device, different flow paths are created for samples and reagents through a multiple stacked system. This allows the saliva sample to flow separately through a fiber glass matrix, which removes the substances that would interfere with the nanoparticle-based sensing system before it mixes with the sensor nanoparticles. The device’s configuration also helps to regulate the flow in the test strip, generating uniform test lines for more accurate results. The stacking flow immunoassay platform requires only one user activation step: both the sample and reagents are added at the same time in a single step. Both the sample and reagents react and flow concurrently in the test strip. The single-step procedure significantly improved the ease of usage of the test kit. The study was published on January 12, 2015, in the journal Lab on a Chip.

Related Links:

Institute of Bioengineering and Nanotechnology
Merck Millipore  


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.