We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

EIKEN CHEMICAL

EIKEN CHEMICAL CO., LTD. provides clinical diagnostic aids, including biochemical, immunological, serological, dry ch... read more Featured Products: More products

Download Mobile App




Fecal Testing Effective for Familial Colorectal Cancer Screening

By LabMedica International staff writers
Posted on 12 Nov 2014
Print article
Eiken Chemical\'s OC-SENSOR, a fully automatic machine for immunochemical fecal occult blood test for the early identification colon cancer
The OC-SENSOR, a fully automatic machine for immunochemical fecal occult blood test for the early identification colon cancer (Photo courtesy of EIKEN CHEMICAL)
Fecal immunochemical tests may be as effective as colonoscopies when it comes to detecting colorectal cancer among first-degree relatives of patients with colorectal cancer (CRC).

First-degree relatives of patients with nonsyndromic colorectal cancer (CRC) are at higher risk of developing CRC than the general population and personal risk in these individuals has mostly been related to the age of the index case at diagnosis, degree of kinship, and number of relatives affected.

Gastroenterologists at the Universidad de La Laguna (Tenerife, Spain) conducted a prospective study of 1,918 first-degree relatives of patients with CRC who were randomly assigned to receive a single colonoscopy examination or three fecal immunochemical tests (FITs). One test was done per year for three years; with a cutoff equal to or greater than 10 μg hemoglobin/g feces which corresponds to 50 ng hemoglobin/mL buffer.

Individuals assigned to the FIT group were provided with a single OC-Sensor Fecal Immunochemical Test kit (Eiken Chemical; Tokyo, Japan). The samples were analyzed on Eiken’s automated machine for detecting hemoglobin in stool samples. Participants were asked to keep fecal samples at 4 °C and return them within five days after sampling. Colonoscopies were performed by four experienced endoscopists who were blinded to group assignment.

The repeated FIT screening detected all colorectal cancers and 61% of advanced adenomas, thus proving equivalent to one-time colonoscopy screening in terms of diagnostic yield and tumor staging. However, colonoscopy was superior to the FIT strategy for the detection of non-advanced adenomas. The usefulness of FIT screening as an alternative to colonoscopy in the familial risk population will ultimately depend on the capacity of FIT to improve screening uptake.

The authors concluded that the results of their randomized trial demonstrated in asymptomatic first-degree relatives of patients with CRC that screening with FIT is equivalent to one-time colonoscopy for the detection of advanced neoplasia. In addition, it also provides evidence for the benefit of repeated FIT screening in terms of colonoscopy resources.

Enrique Quintero, MD, PhD, the lead author of the study said, “In our study, repeat FIT screening detected all colorectal cancers in asymptomatic first-degree relatives of patients with colorectal cancer. These findings suggest that FIT screening should potentially be considered for familial screening, especially in populations where colonoscopy capacity is limited and/or compliance with colonoscopy is a concern.” The study was published in the November 2014 issue of the journal Gastroenterology.

Related Links:

Universidad de La Laguna 
Eiken Chemical 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.