We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Oral Fluid Testing Established for Pertussis

By LabMedica International staff writers
Posted on 19 Jun 2014
Print article
Image: Electron micrograph of the bacterium Bordetella pertussis, the causative agent of pertussis (Photo courtesy of Sanofi Pasteur).
Image: Electron micrograph of the bacterium Bordetella pertussis, the causative agent of pertussis (Photo courtesy of Sanofi Pasteur).
Existing surveillance systems for pertussis or whooping cough are inadequate and tend to be biased toward identifying severe cases in infants, as reflected by extremely high reported incidence for this age group.

Bordetella pertussis, the causative agent of pertussis, has been isolated from the nasopharynx by use of conventional microbiological techniques. However, culture requires that a specimen be collected early in the illness and might lack sensitivity because the organism is delicate, and any delay in processing specimens can reduce the probability of isolation.

Microbiologist at Public Health England (Colindale, London, UK) have introduced a new oral fluid testing service that was pilot tested throughout England and Wales. When a case was reported, if the diagnosis had not been confirmed by culture, polymerase chain reaction (PCR), or serologic testing, oral fluid sampling kits were mailed either directly to the patients or to the parents/guardians of patients, as the kit was suitable for use at home, or to their general practitioner. The sampling kit contained an ORACOL saliva collection swab (Malvern Medical Developments Ltd, Worcester, UK).

Oral fluid was eluted from each swab and tested for immunoglobulin G (IgG) against pertussis toxin by enzyme-linked immunoassay (ELISA). During the oral fluid pilot testing period, 2,756 oral fluid kits were sent, 2,587 clinical cases were reported, and 2,443 cases of pertussis were confirmed by at least one laboratory method. Of these confirmed cases, 751 were confirmed by oral fluid testing plus or minus other methods and 591 (24% of all cases) were confirmed by oral fluid testing only, which increased laboratory ascertainment of pertussis by 32%, and a maximal increase of 124% occurred among children 5 to 9 years of age.

The authors concluded that the introduction of serologic testing followed by oral fluid testing has successively narrowed the gap in surveillance for pertussis in England and Wales. Patients whose pertussis was confirmed by oral fluid testing were least likely to be hospitalized, suggesting that milder community cases were being confirmed by this method. Oral fluid testing is an easily administered, noninvasive surveillance tool that could further our understanding of pertussis epidemiology and thereby contribute to decisions on vaccination strategies. The study was published in the June 2014 issue of the journal Emerging Infectious Diseases.

Related Links:
Public Health England
Malvern Medical Developments Ltd.


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.