We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

ELITechGroup

Offers a range of products for in vitro diagnostics in clinical chemistry, hemostasis, microbiology, immunology, and ... read more Featured Products: More products

Download Mobile App




A New Slide-Staining System for Tuberculosis with Highly Flexible Programming

By LabMedica International staff writers
Posted on 12 Jun 2014
Print article
Image: The Aerospray TB Series 2 – full pack (Photo courtesy of the ELItech Group Biomedical Systems).
Image: The Aerospray TB Series 2 – full pack (Photo courtesy of the ELItech Group Biomedical Systems).
An international multicenter study has been carried out to assess the performance of a new generation of slide-staining device. The aim of the study was to evaluate the capability of the instrument to achieve good sensitivity and to adjust the staining to individual circumstances and preferences throughout the world by providing a wide range of staining settings via an intuitive user interface.

According to the World Health Organization (WHO), microscopy of stained sputum samples is recognized as an accurate and economical approach for early detection of pulmonary Tuberculosis (TB) infections. Staining Mycobacterium tuberculosis and other acid-fast bacilli (AFB) require Carbol Fuchsin or Fluorescent staining techniques, both approaches coming with variations. Carbol Fuchsin staining usually utilizes Ziehl-Neelsen or Kinyoun primary stains with either Brilliant Green or Methylene Blue counterstains. Fluorescent staining techniques usually utilize Auramine O or Auramine Rhodamine primary stains and Potassium Permanganate or Thiazine Red as the counterstain. These staining methods are well recognized and it is generally accepted that Fluorescence microscopy provides a more rapid smear examination of stained smears and is more suitable for use in regional laboratories with large workloads. Given the increasing importance of fluorescence staining, the multicenter evaluation of the new system focused particularly on this approach.

ELITechGroup Biomedical Systems (Logan, UT, USA) has developed a new Aerospray TB Stainer/Cytocentrifuge (Model 7722). Like previous Aerospray TB models, this stainer automates the staining process of microscope slides without any risk of cross-contamination. The stainer utilizes significantly less stain than manual staining techniques and stains slides in only a quarter of the time usually required by manual staining. The optional Cytocentrifuge function of the instrument allows users to prepare samples evenly and uniformly on the microscope slide prior to staining, which is a significant advantage to increase the overall sensitivity of TB screening in patients with extra- pulmonary TB or with HIV co-infection.

The new Aerospray TB “series 2” utilizes a state-of-the-art touchscreen user interface and provides traceability for users, samples, and reagents. Above all, it is customizable to each laboratory’s needs, yet simple to operate. Various reagent combinations and stain routine adjustments are available in order to achieve the needs of AFB staining in the laboratory.

The stainer has been used in an international study carried out in Belgium, Namibia, South Africa, and USA, which included over 500 samples. These samples included direct and digested specimens (N-Acetylcystein – Phosphate buffer method), stained with different reagent combinations. Each sample was made in duplicate. At least one slide from each sample was stained by manual staining techniques and at least one slide was stained on the new Aerospray TB stainer. The slides were classified as AFB negative or AFB positive. The slide stained on the stainer was classified the same as the manually stained slide on >99.6% of the samples, thus demonstrating the high correlation between the automated and manual approaches.

Dennis Briscoe, General Manager of ELITechGroup Biomedical Systems said, “With the series 2 Aerospray TB (Model 7722), we’ve maintained the unique advantages of the Aerospray stainers and introduced a new slide-staining system for tuberculosis with highly flexible programming, good sensitivity and a user interface that is intuitive enough for routine clinical use.”

Related Links:

The ELITech Group


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.