We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
RANDOX LABORATORIES

Roche Diagnostics

Develops, manufactures, and markets a wide range of in vitro diagnostic systems, instruments, reagents, and tests read more Featured Products: More products

Download Mobile App




Novel Assay Measures Interleukin-6 in Whole Blood Samples

By LabMedica International staff writers
Posted on 05 Oct 2021
Interleukin 6 (IL-6) is a pleiotropic cytokine produced by various stromal cells and immune system cells, involved in inflammation and infection responses, regeneration process, metabolism regulation, bone homeostasis, and neural functions.

Interleukin 6 assays are useful in early detection of infections and risk stratification of critically ill patients, so an assay with a short turnaround-time and near-patient use is preferred. More...
It is indicated in many diseases such as infection, injury, trauma, stress, neoplasia, post-surgery complications, and chronic inflammatory diseases.

Clinical Laboratorians at the Children’s Hospital of Fudan University (Shanghai, China) included in a study pediatric patients, admitted to the Emergency Department (ED) between April and September 2020 with suspected infection. Blood samples and respiratory tract samples were collected for routine clinical laboratory tests, that is, hematology tests, CRP, PCT, viral antigen, or antibody tests and microbiology culture tests.

The study evaluated the performance of the Pylon IL-6 assay (ET Healthcare, Shanghai, China) based on a cyclic enhanced fluorescent immunoassay performed on a fully automated, benchtop Pylon 3D immuno-analyzer. A total of 100 remnant serum samples from outpatients and ED patients were measured by the Pylon assay and the Elecsys IL-6 assay on a Cobas e 602 (Roche Diagnostics, Rotkreuz, Switzerland). The team carried out imprecision, linearity and comparison studies using serum and plasma samples according to CLSI EP guidelines. The stability of whole blood (WB) samples during storage was assessed.

The investigators reported that the results of serum samples measured by Pylon assays correlated to those measured by Roche assays, as well as to those of matched whole blood samples measured by Pylon assays. IL-6 in whole blood was found stable for ~8 hours at room temperature. Pylon IL-6 results of whole blood samples from 179 pediatric patients with suspected infection showed an AUC of 0.842 in diagnosis of bacterial infection. The within-run CVs and total CVs of Pylon IL-6 assay were determined as 1.8% and 3.0% at 159.3 pg/mL and 3.5% and 4.7% at 8009.9 pg/mL, respectively. The method showed linearity between 1.5 and 42,854 pg/mL. The turnaround time of Pylon IL-6 assay was only an hour when using whole blood samples.

The authors concluded that the new Pylon IL-6 assay demonstrated comparable performance to those assays performed on clinical laboratory instruments. Further, the feature of WB sampling offers advantages in ED or other near-patient settings where turnaround time (TAT) is critical. The study was published on September 20, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Children’s Hospital of Fudan University
ET Healthcare
Roche Diagnostics



Gold Member
Clinical Chemistry Assay
Sorbitol Dehydrogenase (SDH)
Online QC Software
Acusera 24•7
HPV Test
Allplex HPV28 Detection
Rapid Sepsis Test
SeptiCyte RAPID
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Researchers use a novel immobilized liposome-bound gel beads method to measure CEC levels and their association with cardiovascular risks (Photo courtesy of Institute of Science Tokyo)

Simple Blood-Based Cholesterol Efflux Assay Identifies High-Risk Coronary Plaque Features

Unstable coronary plaques are difficult to identify before they trigger acute cardiovascular events. Standard high-density lipoprotein (HDL) measurements do not always capture how well HDL particles function... Read more

Pathology

view channel
Image: Overview of the uncertainty-aware lensfree computational pathology platform for automated HER2 assessment. A compact lensfree holographic imaging system captures diffraction patterns from immunohistochemically stained breast tissue samples, which are computationally reconstructed and analyzed using deep neural networks with Bayesian uncertainty quantification. (Photo courtesy of Ozcan Lab, UCLA)

Uncertainty-Aware AI Platform Supports Automated HER2 Assessment in Breast Cancer

Accurate assessment of human epidermal growth factor receptor 2 (HER2) is critical for breast cancer diagnosis and treatment selection, yet scoring variability and infrastructure requirements can complicate... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.