We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Vicotex

Roche Diagnostics

Develops, manufactures, and markets a wide range of in vitro diagnostic systems, instruments, reagents, and tests read more Featured Products: More products

Download Mobile App




Novel Assay Measures Interleukin-6 in Whole Blood Samples

By LabMedica International staff writers
Posted on 05 Oct 2021
Interleukin 6 (IL-6) is a pleiotropic cytokine produced by various stromal cells and immune system cells, involved in inflammation and infection responses, regeneration process, metabolism regulation, bone homeostasis, and neural functions.

Interleukin 6 assays are useful in early detection of infections and risk stratification of critically ill patients, so an assay with a short turnaround-time and near-patient use is preferred. More...
It is indicated in many diseases such as infection, injury, trauma, stress, neoplasia, post-surgery complications, and chronic inflammatory diseases.

Clinical Laboratorians at the Children’s Hospital of Fudan University (Shanghai, China) included in a study pediatric patients, admitted to the Emergency Department (ED) between April and September 2020 with suspected infection. Blood samples and respiratory tract samples were collected for routine clinical laboratory tests, that is, hematology tests, CRP, PCT, viral antigen, or antibody tests and microbiology culture tests.

The study evaluated the performance of the Pylon IL-6 assay (ET Healthcare, Shanghai, China) based on a cyclic enhanced fluorescent immunoassay performed on a fully automated, benchtop Pylon 3D immuno-analyzer. A total of 100 remnant serum samples from outpatients and ED patients were measured by the Pylon assay and the Elecsys IL-6 assay on a Cobas e 602 (Roche Diagnostics, Rotkreuz, Switzerland). The team carried out imprecision, linearity and comparison studies using serum and plasma samples according to CLSI EP guidelines. The stability of whole blood (WB) samples during storage was assessed.

The investigators reported that the results of serum samples measured by Pylon assays correlated to those measured by Roche assays, as well as to those of matched whole blood samples measured by Pylon assays. IL-6 in whole blood was found stable for ~8 hours at room temperature. Pylon IL-6 results of whole blood samples from 179 pediatric patients with suspected infection showed an AUC of 0.842 in diagnosis of bacterial infection. The within-run CVs and total CVs of Pylon IL-6 assay were determined as 1.8% and 3.0% at 159.3 pg/mL and 3.5% and 4.7% at 8009.9 pg/mL, respectively. The method showed linearity between 1.5 and 42,854 pg/mL. The turnaround time of Pylon IL-6 assay was only an hour when using whole blood samples.

The authors concluded that the new Pylon IL-6 assay demonstrated comparable performance to those assays performed on clinical laboratory instruments. Further, the feature of WB sampling offers advantages in ED or other near-patient settings where turnaround time (TAT) is critical. The study was published on September 20, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Children’s Hospital of Fudan University
ET Healthcare
Roche Diagnostics



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Electrolyte Analyzer
CBS-4000 (CBS-400)
CMV CLIA Diagnostic
CLIA CMV IgA Screen Group
New
Gold Member
Platelet Function Analyzer
PL-12
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image Credit: Adobe Stock

Single Genetic Analysis Identifies Causes of Premature Ovarian Insufficiency

Premature ovarian insufficiency (POI) affects up to 3.5% of women and represents a major cause of infertility. In most cases, the underlying etiology remains unknown, making patient counseling and clinical... Read more

Microbiology

view channel
Image: The “broth” used to monitor red blood cell depletion in whole blood spiked with one colony-forming-unit of E. coli bacteria, each incubated at different orbital shaking speeds—left to right: 0 RPM, 65 RPM, 120 RPM and 200 RPM—after four hours of incubation. This culturing raises a bacteria-rich, plasma-like layer of bacteria to the top of the vials, while clusters of stuck blood cells known as a Rouleaux formation sink to the bottom. (Image Credit: Pak Kin Wong)

New Diagnostic Workflow Identifies Bloodstream Pathogens and Antibiotic Response in Hours

Sepsis is a life-threatening complication of infection that affects more than 1.5 million patients annually in the United States and contributes to roughly one in three in-hospital deaths.... Read more

Pathology

view channel
Image: Researchers evaluated AI models that quantify tumor-infiltrating lymphocytes (TIL) on routine breast tissue slides, where higher TIL levels reflect stronger antitumor response and improved breast cancer outcomes (Image Credit: Shutterstock)

AI Matches Pathologists in Predicting Breast Cancer Prognosis from Immune Cells

Breast cancer is the most common cancer in Australian women, with more than 20,000 cases each year. Prognosis can be informed by counting tumor-infiltrating lymphocytes (TILs) on routine pathology slides,... Read more

Industry

view channel
Image: RaDaR ST uses a tumor-informed approach that identifies up to 48 patient-specific variants through whole-exome sequencing and tracks those variants in plasma to detect circulating tumor DNA (ctDNA) at very low variant allele fractions (VAFs) (Photo courtesy of Neogenomics)

Tumor-Informed MRD Assay Gains Medicare Coverage for Immunotherapy Monitoring

NeoGenomics’ RaDaR ST molecular residual disease (MRD) assay has received expanded coverage from the Centers for Medicare & Medicaid Services’ Molecular Diagnostic Services Program (MolDX) for monitoring... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.