First-of-Its-Kind Wearable, Non-Invasive and Needle-Free Device Monitors Glucose Levels in Sweat

By LabMedica International staff writers
Posted on 18 Oct 2021
Print article
Image: Wearable, Non-invasive Glucose Sensor (Photo courtesy of Jia Zhu)
Image: Wearable, Non-invasive Glucose Sensor (Photo courtesy of Jia Zhu)

Researchers have developed a prototype of a wearable, non-invasive glucose sensor to be worn on the arm that could make less intrusive glucose monitoring the norm.

The first-of-its-kind wearable, non-invasive low-cost sensor developed by researchers at Penn State (University Park, Pa.) can detect glucose in sweat. Non-invasive glucose monitoring devices are not currently commercially available in the US, so people with diabetes must collect blood samples or use sensors embedded under the skin to measure their blood sugar levels. The researchers constructed the device first with laser-induced graphene (LIG), a material consisting of atom-thick carbon layers in various shapes. With high electrical conductivity and a convenient fabrication time of just seconds, LIG appeared to be an ideal framework for the sensing device - but there was a significant caveat.

The team chose nickel because of its robust glucose sensitivity and combined it with gold to lower potential risks of an allergic reaction. The researchers hypothesized that the LIG outfitted with the nickel-gold alloy would be able to detect low concentrations of glucose in sweat on the skin’s surface. A material with high glucose sensitivity was a priority. Sweat exhibits remarkably low glucose concentrations compared to blood, although there is a strong correlation between glucose levels in sweat and blood. While the concentration of glucose in sweat is about 100 times less than the concentration in blood, the team’s device is sensitive enough to accurately measure the glucose in sweat and reflect the concentration in blood.

The nickel-gold alloy’s sensitivity allowed the team to exclude enzymes, which are often used to measure glucose in more invasive, commercially available devices or in non-invasive monitors proposed by other researchers. These enzymes, however, can degrade quickly with time and changing temperatures. Non-enzymatic sensors require alkaline solution, which can damage the skin and typically limits device wearability. To curb this issue, the researchers attached a microfluidic chamber to the LIG alloy. This chamber is smaller than previously developed configurations to promote wearability and porous to allow for a range of movement, such as stretching or crushing. It is connected to a collection inlet that passes sweat into the solution without allowing the solution to touch the skin. The basic solution interacts with the glucose molecules to produce a compound that reacts with the alloy. This reaction triggers an electrical signal, indicating the concentration of glucose in the sweat.

With a smaller alkaline solution chamber, the entire device is roughly the size of a quarter and is flexible enough to maintain a secure attachment to the human body. In a proof-of-concept test, the researchers used a skin-safe adhesive to attach the reusable device to a person’s arm one hour and three hours after a meal. The subject performed a brief workout - just enough to produce sweat - right before each measurement time. A few minutes after collecting the sweat, the researchers found that the detected glucose concentration dropped from the first measurement to the next. The glucose measurements from the device were verified by measurements made with a commercially available glucose monitor.

The researchers now plan to improve upon their prototype for future applications, including addressing how patients or clinicians may use the sensor for incremental glucose measurements or continuous monitoring to determine treatment actions, such as administering insulin. They also intend to refine and expand this platform for more comfortable monitoring of other biomarkers that can be found in the sweat or interstitial fluids that fill the space between cells in the body.

“We want to work with physicians and other health care providers to see how we can apply this technology for daily monitoring of a patient,” said Huanyu “Larry” Cheng, Dorothy Quiggle Career Development Professor in Penn State's Department of Engineering Science and Mechanics, who led the study. “This glucose sensor serves as a foundational example to show that we can improve the detection of biomarkers in sweat at extremely low concentrations.”

Related Links:
Penn State 

Gold Supplier
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
New
Anti-SARS-CoV-2 Controls Kit
ACCURUN Anti-SARS-CoV-2 Controls Kit
New
Cardiovascular Disease POC Analyzer
cobas h 232 POC System
New
Cytology Sample Processor
SDSCP9000 CytoPath Processor

Print article

Channels

Hematology

view channel
Image: Atellica Solution (Photo courtesy of Siemens Healthineers)

Siemens Introduces New Intelligent, Integrated IVD Solutions Virtually at EUROMEDLAB 2021

Siemens Healthineers (Erlangen, Germany) introduced new intelligent, integrated IVD solutions virtually at the XXIV IFCCEFLM European Congress of Clinical Chemistry and Laboratory Medicine (EuroMedLab... Read more

Immunology

view channel
Image: The Luminex 200 Instrument System sets the standard for multiplexing, providing the ability to perform up to 100 different tests in a single reaction volume on a flow cytometry-based platform (Photo courtesy of Luminex Corp)

Inflammatory Cytokines Measured in Infants Born to Preterm Preeclamptic Mothers

Preeclampsia is both a vascular and inflammatory disorder. The pathophysiology of preeclampsia is complex and rooted in the interplay between maternal and placental factors with the key characteristics... Read more

Microbiology

view channel
Image: The sciREADER CL2 enables high quality digital colorimetric imaging of various support formats (Photo courtesy of SCIENION)

Multiplex Immunoassay Developed for Confirmation and Typing of HTLV Infections

Human T-Cell Lymphotropic Viruses (HTLV) type 1 and type 2 account for an estimated five to 10 million infections worldwide and are transmitted through breast feeding, sexual contacts and contaminated... Read more

Pathology

view channel
Image: The Ventana BenchMark Ultra autostainer is for cancer diagnostics with automation and the test menu include IHC, ISH, and FITC tests (Photo courtesy of Ventana Medical System)

Specific Biomarker Investigated for Triple-Negative Breast Cancer Diagnosis

Triple-negative breast cancer (TNBC) is defined by the lack of estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) expression and comprises a heterogeneous... Read more

Industry

view channel
Illustration

Global Lateral Flow Assay Market to Reach Nearly USD 6.5 Billion by 2031 Due to Surge in Demand for Rapid POC Testing

The global lateral flow assay market is projected to grow at a CAGR of around 5% from USD 3.7 billion in 2020 to over USD 6.4 billion by 2031, driven by the growing adoption of home-based lateral flow... Read more
Copyright © 2000-2021 Globetech Media. All rights reserved.