We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Unexpected Prevalence of High-Risk HPV Types Demonstrated

By LabMedica International staff writers
Posted on 13 Jun 2019
Print article
Image: The SLAN-96 real-time polymerase chain reaction (PCR) instrument (Photo courtesy of QuanDx/Zeesan Biotech).
Image: The SLAN-96 real-time polymerase chain reaction (PCR) instrument (Photo courtesy of QuanDx/Zeesan Biotech).
Low- and middle-income countries have high incidences of cervical cancer linked to human papillomavirus (HPV), and without resources for cancer screenings these countries bear 85% of all cervical cancer cases.

In many of these countries, cervical cancer is the leading cause of cancer-related mortality and attributable to limited screening programs. A lack of funding, trained cytopathologists to review Papanicolaou test slides, and other health care providers for follow-up care that comprise the needed infrastructure does not allow for routine cervical cancer screening.

Scientists from Dartmouth College (Lebanon, NH, USA) and their Honduran colleagues collected cervical samples using cervical brushes on 1,732 participants who were employees at a manufacturing site in San Pedro Sula, Honduras, for Papanicolaou test and hrHPV testing. All cervical brushes and corresponding Papanicolaou test slides were assigned a unique study identification number.

After processing the dried cervical brushed were rehydrated in the assay tubes that contained lyophilized reagents for the MeltPro High Risk HPV Genotyping Assay. Rehydrated reagents with cell lysate were then mixed and loaded directly onto the QuanDx/Zeesan Biotech SLAN-96 real-time polymerase chain reaction (PCR) instrument and run using the SLAN 8.2.2 software and HPV typing results were available within 2.5 hours.

The QuanDx assay detects and distinguishes all 14 high-risk HPV types, as well as an internal human DNA sequence control. The scientists found that 480 of the 1,732 samples from the factory worker screening effort were positive for high-risk HPV, or approximately 28%, while 1,199 samples had no detectable HPV, and 53 samples failed to amplify either the internal control or an HPV target and were deemed to be invalid. The most common genotypes detected in the study were HPVs 58, 35, and 16. Specifically, HPV 58 was detected in 90 samples, or among 19 % of positive samples, while HPV 35 was detected in 64 samples, or among 13% of positive samples, and HPV 16 was detected in 63 samples, also approximately 13% of all of positive infections.

Gregory J. Tsongalis, PhD, director of the laboratory for clinical genomics and senior author of the study, said, “This is a very robust assay with relatively high throughput and it can differentiate between all high-risk and low-risk HPV types in two separate assays. The team put the assay through "a very rigorous validation" before deploying it.” The study was published on May 3, 2019, in the Journal of Global Oncology.

Related Links:
Dartmouth College

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.