We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Method Developed to Detect AFP and GP73 Simultaneously

By LabMedica International staff writers
Posted on 05 Jun 2018
Print article
Image: The Luminex 200 System is a flexible analyzer based on the principles of flow cytometry (Photo courtesy of Luminex).
Image: The Luminex 200 System is a flexible analyzer based on the principles of flow cytometry (Photo courtesy of Luminex).
Liver cancer is the second leading cause of cancer death in males and the sixth in females worldwide. An estimated 782,500 new liver cancer cases and 745,500 deaths occurred worldwide during 2012.

Alpha-fetoprotein (AFP) is a biomarker that is commonly used in the clinic for Hepatocellular Carcinoma (HCC) diagnosis and to predict HCC progression especially in chronic hepatitis B (HBV) infected patients. Golgi protein 73 (GP73) is a biomarker for advanced liver diseases and the increase in GP73 levels is correlated with various liver diseases.

Scientists at Capital Medical University, Beijing, PR China) used anti-human AFP and GP73 monoclonal antibodies to develop a sandwich immunity reaction using xMAP technology for the simultaneous detection of plasma AFP and GP73. The assay evaluated the sensitivity, cross reactivity, range of detection, precision, recovery and linearity dilution effect. The assay utilized plasma samples and compared its performance with commercially available Enzyme Linked Immunosorbent Assay (ELISA) kits. The team used the Luminex-200 analyzer and the iMark microplate reader.

The scientists analyzed 80 clinical plasma samples using the Luminex multiplex assay system and commercially available ELISA kits. The correlation coefficient of AFP and GP73 were 0.997 and 0.959 respectively. The results showed that the AFP levels from HCC patient samples were significantly higher than from patient samples with liver cirrhosis and healthy controls. However, AFP levels in patients with liver cirrhosis were not significantly different from that of healthy controls. The GP73 levels of samples from HCC and liver cirrhosis patients were significantly higher than healthy controls; however, the GP73 levels from patients with HCC and liver cirrhosis were not significantly different.

The authors concluded that they have established a new method to detect AFP and GP73 levels in plasma samples simultaneously using the Luminex xMAP technology. The method demonstrated a sensitive, effective, and accurate method and the assay could be used clinically for routine detection and monitoring of patients with HBV related diseases. The study was published in the July 2018 issue of the journal Clinica Chimica Acta.

Related Links:
Capital Medical University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.