We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Quick Test Detects Inflammation in Diabetic Patients

By LabMedica International staff writers
Posted on 12 Oct 2016
Print article
Image: Professor Bernhard Boehm and Dr Hou Han Wei holding their quick test kit for inflammation in diabetic patients (Photo courtesy of Nanyang Technological University).
Image: Professor Bernhard Boehm and Dr Hou Han Wei holding their quick test kit for inflammation in diabetic patients (Photo courtesy of Nanyang Technological University).
A new kit has been developed that will allow doctors to find out within minutes if diabetic patients are suffering from inflammation. Current procedures require patients to wait for several hours for the results obtained from the conventional full blood count test.

Type 2 diabetes is the most common and is usually treated with lifestyle changes, medication and insulin. If diabetic patients can be grouped based on their inflammation status in addition to glucose level, then doctors can better choose the treatment best suited for their patients.

Scientists at the Nanyang Technological University (Singapore) and their colleagues have developed a rapid microfluidic neutrophil sorting and functional phenotyping strategy for type 2 diabetes mellitus (T2DM) patients using small blood volumes from a fingerprick of ~100 μL. The developed inertial microfluidics technology enables single-step neutrophil isolation of greater than 90% purity without immuno-labeling and sorted neutrophils are used to characterize their rolling behavior on E-selectin, a critical step in leukocyte recruitment during inflammation. Flow cytometry analysis was performed using BD LSR Fortessa flow cytometer (BD Biosciences, San Jose, CA, USA).

The team discovered that neutrophils can be used as a biomarker to determine if diabetic patients are suffering from an inflammation. Using the new test kit, neutrophils can be easily extracted from a blood sample, and their behavior and function observed for more efficient inflammation profiling in additional to the cell count. In healthy individuals, neutrophils float free in the blood stream. When there is an acute inflammation such as during a bacterial or viral infection, they will slow down and roll along the vessel walls.

Once near the site of infection, the neutrophils squeeze through the vessel walls and move to the site of the injury. In diabetic patients, the neutrophils roll faster, which means that fewer of them will manage to squeeze through the vessel wall to tackle the infection. The increased rolling speeds of neutrophils correlate closely with cholesterol and C-reactive protein levels, a biomarker for inflammation, so it provides doctors with a better indicator of an individual's immune status.

The authors concluded that their results suggest a new point-of-care testing methodology, and neutrophil rolling speed as a functional biomarker for rapid profiling of dysmetabolic subjects in clinical and patient-oriented settings. This new test kit will advance diabetes management by providing real-time signals related to a cluster of risk factors faced by patients. It will lead the way to improvements in patient care, enabling chronic disease self-management and finally a healthier society. The study was published on September 27, 2016, in the journal Scientific Reports.

Related Links:
Nanyang Technological University
BD Biosciences
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.