Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

EUROIMMUN AG

EUROIMMUN is an international provider of medical laboratory products for autoimmune, infection, allergy and molecula... read more Featured Products: More products

Download Mobile App




Increased Serum Cytokine Concentrations Reported in Guillain-Barré Syndrome

By LabMedica International staff writers
Posted on 05 Oct 2016
Guillain-Barré syndrome (GBS) is an acquired demyelinating peripheral neuropathy and it has been shown that macrophage activation contribute to the pathogenesis of GBS. Therefore macrophage-mediated factors could be the potential markers for disease diagnosis and status of GBS.

The diagnosis of GBS is based on a combination of clinical, electrophysiological features as well as analysis of the cerebrospinal fluid (CSF). A biomarker that can be evaluated as an indicator of a pathological process or pharmacological response to a therapeutic intervention could assist in the clinical diagnosis, monitoring disease progression, and testing the efficacy of immunotherapy in GBS.

Scientists at the Chang Gung University College of Medicine (Taoyuan, Taiwan) measured serum concentrations of four macrophage-mediated factors, including interleukin-6 (IL-6), transforming growth factor-β1 (TGF-β1), vascular cell adhesion protein 1 (VCAM-1) and vascular endothelial growth factor (VEGF), in 23 chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), 28 GBS, 11 Miller-Fisher syndrome (MFS), 40 multiple sclerosis (MS), and 12 Alzheimer's disease (AD) patients, as well as 15 healthy controls.

Serum concentrations of IL-6, TGF-β1, VEGF and VCAM-1 were assessed using enzyme-linked immunosorbent assay (ELISA) (R&D Systems, Minneapolis, MN, USA). Anti-ganglioside (anti-GD1a, anti-GD1b, anti-GM1, anti-GM2, anti- GM3, anti-GQ1b and anti-GT1b) and anti-neuronal antigen (anti- AMPHIPHYSIN, anti-CV2, anti-Hu, anti-Ma2, anti-RECOVERIN, anti-Ri, anti-SOX1, anti-TITIN and anti-Yo) immunoglobulin G (IgG) autoantibodies were measured by using immunoblot strip kit (Euroimmun AG, Luebeck, Germany).

The investigators found that serum TGF-β1 concentration of GBS patients at 35.94 ± 2.55 ng/mL was statistically significantly higher compared with CIDP with a mean of 25.46 ± 1.40 ng/mL, for MFS at 25.32 ± 2.31 ng/mL, MS equaled 21.35 ± 0.90 ng/mL, and AD patients at 22.92 ± 1.82 ng/mL, as well as healthy controls with 23.12 ± 1.67 ng/mL. A positive correlation between serum TGF-β1 concentrations and Hughes' functional grading scales was observed in GBS patients. Serum concentrations of IL-6, VCAM-1 and VEGF were similar between the studied groups. The CSF concentration of TGF-β1 was undetectable by the assay they used.

The authors concluded that that serum concentration of TGF-β1was increased in GBS patients compared to patients with other neurological diseases, including CIDP, MFS, MS and AD, as well as control subjects. These findings implicate TGF-β1 may be involved in the compensatory response to the inflammatory process of GBS. The study will be available in the October 2016 issue of the journal Clinica Chimica Acta.

Related Links:
Chang Gung University College of Medicine
R&D Systems
Euroimmun

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.