We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Fecal Immunochemical Test Effective for Annual Colon Cancer Screening

By LabMedica International staff writers
Posted on 10 Feb 2016
Print article
Image: The fecal immunochemical test (FIT) kit used in screening for colorectal cancer (Photo courtesy of Kaiser Permanente).
Image: The fecal immunochemical test (FIT) kit used in screening for colorectal cancer (Photo courtesy of Kaiser Permanente).
The fecal immunochemical test (FIT) is highly sensitive for detecting colorectal cancer, and adherence to annual follow-up screening among initial participants is high, making the noninvasive test feasible and effective for annual colorectal cancer screening programs.

Colorectal cancer (CRC) is the second leading cause of cancer death in the USA. Evidence shows that highly sensitive guaiac-based fecal occult blood tests (FOBT), which are recommended for annual screening of average risk patients between the ages of 50 and 75, can reduce morbidity and mortality from colorectal cancer. FIT has higher detection rates for CRC and advanced adenomas than FOBT, but little is known about how well FIT works over several rounds of annual screening.

Scientists working for Kaiser Permanente (Oakland, CA, USA) and their colleagues carried out a retrospective cohort study and collected data on 323,349 health plan members aged 50 to 70 years. The members were on their FIT mailing date in 2007 or 2008 and had completed the first round of FIT and were followed for up to four screening rounds. Screening participation included an FIT positivity, equal to or greater than 20 µg of hemoglobin/g, which has positive predictive values for adenoma and CRC, and FIT sensitivity for detecting CRC obtained from Kaiser Permanente electronic databases and cancer registries.

Of the patients invited for screening, 48.2% participated in round one. Of those who remained eligible, 75.3% to 86.1% participated in subsequent rounds. Median follow-up was 4.0 years, and 32% of first round participants crossed over to endoscopy over four screening rounds and 7.0% were due to a positive FIT result. The FIT positivity rate of 5.0% and positive predictive values (adenoma, 51.5%; CRC, 3.4%) were highest in the first round.

Overall, programmatic FIT screening detected 80.4% of patients with CRC diagnosed within one year of testing, including 84.5% in round one and 73.4% to 78.0% in subsequent rounds. The authors concluded that annual FIT screening was associated with high sensitivity for CRC, with high adherence to annual follow-up screening among initial participants. The findings indicate that annual programmatic FIT screening is feasible and effective for population-level CRC screening. The study was published on January 26, 2016, in the journal Annals of Internal Medicine.

Related Links:

Kaiser Permanente


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.