Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

BECKMAN COULTER, INC.

Beckman Coulter develops, manufactures and markets laboratory systems, reagents, centrifugation, lab automation, elec... read more Featured Products: More products

Download Mobile App




Serum Mimecan Associated with Arterial Stiffness in Hypertensive Patients

By LabMedica International staff writers
Posted on 18 Aug 2015
Mimecan plays an important role in endothelial and vascular smooth muscle cell integrity and may be involved the pathology of arterial stiffness; however, the role of mimecan in arterial stiffness in patients with hypertension is not well defined.

Arterial stiffness is recognized to be an independent risk factor for cardiovascular (CV) morbidity and mortality and it is the root cause of a range of CV complications, including myocardial infarction (MI), left ventricular hypertrophy, stroke, renal failure, dementia, and death, as well as a hallmark of the aging process.

Scientists at the Second Affiliated Hospital of Soochow University (Suzhou, China), enrolled a total of 116 hypertension patients and 54 healthy controls to investigated the association between serum mimecan concentration and arterial stiffness, as measured by brachial‐ankle pulse wave velocity (baPWV), in patients with hypertension. Hypertensive patients were divided into two groups: 83 with arterial stiffness defined by a baPWV of equal to or greater than 1,400 cm/s; and the 3, in the without arterial stiffness group, whose baPWV was less than 1,400 cm/s.

Routine biochemical measurements were performed on each blood sample using an AU5400 automated chemistry analyzer (Beckman Coulter; Fullerton, CA, USA). Circulating mimecan concentrations were determined using the human mimecan enzyme-linked immunosorbent assay (ELISA) kit (antibodies‐online Inc., Atlanta, GA, USA) that has a detection range of this kit is 20 ng/mL to 0.313 ng/mL and sensitivity is 0.133 ng/mL. Circulating endothelin 1 (ET‐1) concentrations were determined using the human ET‐1 ELISA kit (R&D Systems; Minneapolis, MN, USA) that has detection range of 0.34 to 250 pg/mL and its sensitivity is 0.102 pg/mL.

Hypertensive patients had higher baPWV, mimecan, and endothelin 1 than healthy controls. Mean mimecan levels were 13.7ng/mL in the hypertensive group compared to 8.32 ng/mL in the healthy controls. The arterial stiffness group had higher mimecan and endothelin 1 (ET‐1) and lower ankle‐brachial pressure index (ABI) than those without stiffness. In hypertensive patients, mimecan was inversely correlated with ABI and positively correlated with baPWV, ET‐1, and total cholesterol. Diastolic blood pressure, mimecan, ET‐1, and creatinine were independent predictors of arterial stiffness in hypertensive patients.

The authors conclude that mimecan levels are higher in hypertensive patients than in healthy controls and increased plasma mimecan levels are independently associated with increased arterial stiffness as assessed by baPWV. The study was published on July 23, 2015, in the Journal of the American Heart Association (JAHA).

Related Links:
Second Affiliated Hospital of Soochow University 
Beckman Coulter 
antibodies‐online Inc. 



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.