Automated Test for Galectin-3 Cleared for Chronic Heart Failure Prognosis

By LabMedica International staff writers
Posted on 21 Jul 2015
Print article
Image: The ARCHITECT ci4100 clinical chemistry and immunoassay testing analyzer (Photo courtesy of Abbott Diagnostics).
Image: The ARCHITECT ci4100 clinical chemistry and immunoassay testing analyzer (Photo courtesy of Abbott Diagnostics).
Higher levels of galectin-3 are associated with a more aggressive form of heart failure, which may make identification of high-risk patients using galectin-3 testing an important part of patient care.

Galectin-3 is a protein that is involved in fundamental disease processes, including the development of fibrosis in organ tissues and cardiac remodeling, which may lead to the development and progression of heart failure.

An automated blood test was officially cleared by the United States Food and Drug Administration (FDA; Silver Springs, MD, USA) for use in conjunction with clinical evaluation as an aid in assessing the prognosis of patients diagnosed with chronic heart failure. The test is an in vitro diagnostic device that quantitatively measures galectin-3 in serum or plasma by enzyme linked immunosorbent assay (ELISA) on a microtiter plate platform.

The ARCHITECT Galectin-3 assay (Abbott Diagnostics; Abbot Park, IL, USA) is a chemiluminescent microparticle immunoassay (CMIA) for the quantitative determination of galectin-3 in human serum and ethylenediaminetetraacetic acid (EDTA) plasma. The ARCHITECT Galectin-3 assay is performed using the Abbott ARCHITECT automated immunoassay analyzer and is being commercialized through an agreement between BG Medicine (Waltham, MA, USA) and Abbott. The ARCHITECT Galectin-3 assay is used with the ARCHITECT i System with STAT protocol capability.

Results should be interpreted along with clinical findings and other laboratory test results. Levels of galectin-3 in blood may be increased in patients with certain cancers and conditions associated with organ fibrosis. The ARCHITECT Galectin-3 assay is not indicated for detection, diagnosis, prognosis, or any uses associated with any type of cancer, conditions associated with organ fibrosis, or any other condition.

Paul R. Sohmer, MD, president and CEO of BG Medicine, Inc., said, “We believe that the introduction of automated galectin-3 testing will improve access to galectin-3 testing, shorten turn-around time for delivery of test results, and, as a result, accelerate adoption of galectin-3 testing in the United States.”

Related Links:

United States Food and Drug Administration 
Abbott Diagnostics 
BG Medicine


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The utilization of liquid biopsies in cancer research is a rapidly developing field (Photo courtesy of Lightspring/Shutterstock)

Blood Samples Enhance B-Cell Lymphoma Diagnostics and Prognosis

B-cell lymphoma is the predominant form of cancer affecting the lymphatic system, with about 30% of patients with aggressive forms of this disease experiencing relapse. Currently, the disease’s risk assessment... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Pathology

view channel
Image: The Sampler device could revolutionize sample collection for diagnostic tests (Photo courtesy of ReadyGo Diagnostics)

First of Its Kind Universal Tool to Revolutionize Sample Collection for Diagnostic Tests

The COVID pandemic has dramatically reshaped the perception of diagnostics. Post the pandemic, a groundbreaking device that combines sample collection and processing into a single, easy-to-use disposable... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.