We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Donor-Linked Biomarker Predicts Likelihood of Liver Transplant Success

By LabMedica International staff writers
Posted on 31 Aug 2021
Print article
Image: A healthy human liver. A biomarker linked to the organ donor predicts the likelihood that a transplanted liver will be accepted or rejected by the recipient of the organ (Photo courtesy of  Wikimedia Commons)
Image: A healthy human liver. A biomarker linked to the organ donor predicts the likelihood that a transplanted liver will be accepted or rejected by the recipient of the organ (Photo courtesy of Wikimedia Commons)
A recent paper identified a biomarker linked to the organ donor that predicts the likelihood that a transplanted liver will be accepted or rejected by the recipient of the organ.

Compatibility between donor and recipient depends on the similarity of the HLA (human leukocyte antigen) proteins expressed by both. A measure of this similarity is the HLA evolutionary divergence (HED), a continuous metric that quantifies the peptidic differences between two homologous HLA alleles, reflecting the size of the immunopeptide region resented to T-lymphocytes.

In this recent paper, investigators at Assistance Publique, Hôpitaux de Paris, (France) sought to assess the potential effect of donor or recipient HED on liver transplant rejection.

For this study, they accessed the medical records of 1154 adults and 113 children who had a liver transplant between 2004 and 2018. Liver biopsies were done one, two, five, and 10 years after the transplant and in case of liver dysfunction. Donor-specific anti-HLA antibodies (DSAs) were measured in children at the time of biopsy. The HED was calculated using the physicochemical Grantham distance for class I (HLA-A or HLA-B) and class II (HLA-DRB1 or HLA-DQB1) alleles. Grantham's distance depends on three properties: composition, polarity and molecular volume. According to Grantham's distance, the most similar amino acids are leucine and isoleucine and the most distant are cysteine and tryptophan.

The influence of HED on the incidence of liver lesions was analyzed through the inverse probability weighting approach based on covariate balancing, generalized propensity scores.

Data obtained during the study showed that in adults, class I HED of the donor was associated with acute rejection, chronic rejection, and ductopenia of 50% or more but not with other histologic lesions. In children, class I HED of the donor was also associated with acute rejection independent of the presence of DSAs. There was no effect of either donor class II HED or recipient class I or class II HED on the incidence of liver lesions in adults and children. Thus, HED calculated from the HLA alleles of the donor had a much stronger influence on liver transplant success than HLA compatibility. The higher the HED of a donor of liver graft, the more frequent rejection, and this was completely independent of the HLA compatibility of donors and recipients.

These findings allowed the investigators to conclude, “Class I HED of the donor predicts acute or chronic rejection of liver transplant. This novel and accessible prognostic marker could orientate donor selection and guide immunosuppression.”

The study was published in the August 24, 2021, online edition of the journal Annals of Internal Medicine.

Related Links:
Assistance Publique, Hôpitaux de Paris

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.