DNA Extraction Technique Improved for Chagas Diagnosis

By LabMedica International staff writers
Posted on 28 Jan 2019
Print article
Image: Trypanosoma cruzi in thin blood smears stained with Giemsa (Photo courtesy of Centers of Diseases Control and Prevention).
Image: Trypanosoma cruzi in thin blood smears stained with Giemsa (Photo courtesy of Centers of Diseases Control and Prevention).
Chagas disease, caused by the protozoan parasite Trypanosoma cruzi, is endemic in many parts of the Americas, where six to seven million people are infected. In the acute phase of the infection, serology may still be negative but positive for parasite by microscopic examination or by culture in specialized medium.

The Polymerase Chain Reaction (PCR) has become an important and sensitive diagnostic tool. The test is highly sensitive for diagnosis of acute and congenital Chagas disease. Conventional PCR has several drawbacks, especially cross-contamination. For this reason, quantitative PCR (qPCR) has now been more widely used and accepted.

Scientists at the Cayetano Heredia University (Lima, Peru) and their colleagues improved and developed a more sensitive method to recover parasite DNA from clot samples for the diagnosis of Chagas disease. A total of 265 match pair samples of whole blood–guanidine (GEB) and clot samples were analyzed; 150 were from Chagas seropositive subjects. DNA was extracted from both whole blood-guanidine samples, using a previously standardized methodology, and from clot samples, using a newly developed methodology based on a combination of the FastPrep technique and the standard method for GEB extraction.

The blood samples mixed with Guanidine/EDTA (GEB) were processed using the High Pure PCR Template Preparation kit. A duplex qPCR was performed targeting the satellite sequence of the nuclear genome of T. cruzi and the sequence of an internal amplification control. The diagnosis of Chagas disease in human samples was based on serological assays. Enzyme-linked immunosorbent assays (ELISA) were performed using Chagatek Wiener Recombinante v3.0 ELISA. Indirect hemagglutination assay (IHA) was performed using the Chagas Polychaco kit. Western blot analyses were also performed.

The team reported that out of the 265 samples analyzed, 150 samples were from Chagas seropositive individuals. The mean DNA concentration was higher on clot samples than in GEB samples. Of the 150 samples from Chagas positive individuals by serology, 47 samples tested positive by qPCR with DNA extracted by both GEB and clot, but an additional 13 samples tested positive only in DNA extracted from clot. No serology-negative samples resulted positive when tested by qPCR. The agreement between the qPCR using clot DNA and GEB DNA was 95.9%.

The authors concluded that their improved methodology for the detection of T. cruzi DNA using clot samples which might improve early diagnosis and therefore will improve treatment and prognosis of infected individuals, especially of those with low blood loads of parasites. The study was published on January 11, 2019, in the journal PLOS Neglected Tropical Diseases.

Related Links:
Cayetano Heredia University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.