We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Kidney Biopsy Profiles Predict Delayed Graft Function

By LabMedica International staff writers
Posted on 28 Feb 2018
Print article
Image: An histology of an early post-transplant allograft biopsy showing a glomerulus with prominent neutrophil infiltration. A few neutrophils are also seen in the interstitium. These findings can be seen in early stages of hyperacute rejection (Photo courtesy of the University of Pittsburgh Medical Center).
Image: An histology of an early post-transplant allograft biopsy showing a glomerulus with prominent neutrophil infiltration. A few neutrophils are also seen in the interstitium. These findings can be seen in early stages of hyperacute rejection (Photo courtesy of the University of Pittsburgh Medical Center).
The probability of renal graft failure can be assessed for donor kidney biopsies through histological analyses; the potential for delayed graft function is not as easily determined by morphology alone, but could potentially be aided by molecular analysis.

A scientific team led by those at Harvard University Office of Technology Development (Cambridge, MA; USA) used donor renal biopsies for both histological assessments and gene expression analysis. RNA was extracted from tissue and reverse transcribed to complementary DNA (cDNA), which was combined with primers designed for genes that were chosen based on literature review related to delayed graft function.

The scientists used quantitative real-time polymerase chain reaction (PCR) to perform gene expression analyses, comparing biopsies from 16 kidneys that showed primary function upon transplantation with those 16 exhibiting delayed graft function. Delayed graft function described the condition of a patient requiring dialysis within a week of transplantation. From the set of genes that the team selected for comparison between the two renal biopsy groups, there were four that showed increased expression within the delayed graft function biopsy samples.

One of the four genes expressed more highly in delayed graft function samples was annotated as a gene for matrix metallopeptidase 3 (MMP3; stromelysin 1, progelatinase), which are related to inflammation and immune response. The other three genes showing more expression with delayed graft function were categorized as related to metabolism, and they were annotated as retinol-binding protein 4, plasma (RBP4); cytochrome P450, subfamily IIIA (niphedipine oxidase), polypeptide 4 (CYP3A4); and fatty acid binding protein 1, liver (FABP1). For delayed graft function samples, these four genes showed increased expression from about 2.5- to 4.0-fold each. In comparison, for samples with immediate function, expression of these four genes hovered around 1.0-fold, with some signals slightly below 1.0 or between 1.0- and 2.0-fold.

The authors concluded that the results of their study indicated a possible gene fingerprint, with potential to forecast likelihood of delayed graft function for donor renal tissue. They recommended further research to assess the value of this approach in conjunction with existing protocols. The study was presented at the Annual Cutting Edge of Transplantation (CEOT) Meeting held February 8-10, 2018. Phoenix, AZ, USA.

Related Links:
Harvard University Office of Technology Development

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.