Improved Blood Stabilization Used for CTC Profiling

By LabMedica International staff writers
Posted on 24 Jan 2018
Print article
Image: The Amnis ImageStreamX Mark II imaging flow cytometer (Photo courtesy of the University of Alabama at Birmingham).
Image: The Amnis ImageStreamX Mark II imaging flow cytometer (Photo courtesy of the University of Alabama at Birmingham).
A new blood stabilization method significantly prolongs the lifespan of blood samples for microfluidic sorting and transcriptome profiling of rare circulating tumor cells, living cancer cells carried in the bloodstream.

Recent innovations in rare-cell and molecular technologies are rapidly advancing our ability to isolate and characterize circulating tumor cells (CTCs) for the noninvasive detection and monitoring of cancer. CTC-based liquid biopsy technologies have now expanded into a wide spectrum of applications in precision oncology, including predictive biomarker discovery, understanding mechanisms of drug resistance and metastasis, and personalized testing of drug efficacy.

A large team of physicians and scientists at Massachusetts General Hospital (MGH, Boston, MA, USA) and their colleagues took a comprehensive approach that aims to preserve blood in its native state with minimal alterations. To achieve these goals, the team first systematically analyzed the storage conditions that optimally preserve the viability of the diverse cell types in whole blood. The biggest challenge, it turned out, was platelet activation. The team then analyzed a variety of antiplatelet agents and found that glycoprotein IIb/IIIa inhibitors, which are frequently used in cardiovascular medicine, were extremely effective in countering cooling-induced platelet aggregation.

The team used blood specimens from a group of 10 patients with metastatic prostate cancer, and they compared the use of preserved blood against paired fresh samples from the same patients for CTC analysis. Cell viability, leukocyte activation, and platelet–leukocyte adhesion were studied using the ImageStreamX Mark II imaging flow cytometer. Overall, there was 92% agreement in the detection of 12 cancer-specific gene transcripts between the fresh and the preserved samples, and there was 100% agreement in the detection of a transcript called androgen-receptor splice variant 7 (AR-V7). The team highlighted the universal nature of this stabilization approach by pointing to its compatibility with the highly demanding microfluidic CTC-iChip device, which isolates tumor cells by rapid removal of blood cells, implying the potential impact of this work extends beyond cancer detection.

David Miyamoto, MD, PhD, of the MGH Cancer Center and a co-author of the study, said, “The ability to preserve the blood for several days and still be able to pick up this clinically relevant biomarker is remarkable. This is very exciting for clinicians, because AR-V7 mRNA can only be detected using CTCs and not with circulating tumor DNA or other cell-free assays.” The study was originally published online on November 23, 2017, in the journal Nature Communications.

Related Links:
Massachusetts General Hospital


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.