We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

Download Mobile App




Assay Identifies Patients Benefiting from Cancer Immunotherapies

By LabMedica International staff writers
Posted on 14 Nov 2017
Print article
Image: An immunohistochemistry of PharmDX 22c3 staining of non-small-cell lung carcinoma (Photo courtesy of Agilent).
Image: An immunohistochemistry of PharmDX 22c3 staining of non-small-cell lung carcinoma (Photo courtesy of Agilent).
Programmed cell death ligand 1 (PD-L1) has been detected in up to 50% of all human cancers, and has become a major focus of therapeutic and biomarker studies.

Patients with cancers expressing the PD-L1 protein are more likely to respond to certain immuno-oncology therapeutics, and several PD-L1-related immuno-oncology therapies have received official approval. A test that delivered PD-L1 results from plasma read out as continuous variables may be of increased utility in the selection of therapeutic options.

A team of scientists collaborating with those at Pinehurst Medical Clinic-East (Pinehurst, NC, USA) focused this test development on mechanisms of blood-based testing for sensitive measurement of circulating RNA using droplet digital polymerase chain reaction (ddPCR). Specifically, they optimized methods for the detection of PD-L1 transcripts recovered from platelet-enriched plasma. Specimens for feasibility and development included tumor derived cell lines, activated and resting immune cells, 38 normal donor plasma and 79 non-small-cell lung carcinoma (NSCLC) donor plasma. They collected a total of 43 tissue and blood samples to assess the potential for concordance with tissue testing,

The team used an assay developed by Biodesix, Inc (Boulder, CO, USA) with the ddPCR and found that of the 79 NSCLC donor specimens initially evaluated with the RNA blood test, they observed a frequency of 62% positive samples with highly variable levels of plasma PD-L1 (2 - 774 copies). They then evaluated a subset of a sample cohort with the PharmDX 22c3 immunohistochemistry (IHC) tissue test result. Although there was poor concordance with a 50% positive IHC cut-off, when they used a variable threshold based on a logistic regression score for the blood assay and the 1% cut-off, concordance of up to 80% was observed between the two assays.

The authors concluded that they have developed sensitive and specific methods that measure the dynamic range of PD-L1 in circulation. This assay is capable of measuring PD-L1 in circulation that arises from activated immune cells and/or tumor cells. They have identified a preliminary threshold for the PD-L1 circulating blood test in development that shows concordance with tissue IHC when using the 22c3 clone at 1% cut-off.

Michael Pritchett, DO, MPH, the lead author of the study, said, “Measurement of PD-L1 is challenging not only when tissue is lacking, but due to the inherent complexity of immunohistochemistry. The testing approach demonstrated in this study shows promise as a method of assessing PD-L1 in plasma. A more objective measure of PD-L1 status could offer a path to better patient care decisions in the treatment of non-small cell lung cancer.” The study was presented on October 28, 2017, at the AACR-NCI-EORTC conference held in Philadelphia, PA, USA.

Related Links:
Pinehurst Medical Clinic-East
Biodesix

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.