Performance of Hematology Analyzer and Peripherals Evaluated

By LabMedica International staff writers
Posted on 05 Oct 2016
Print article
Image: The CAL 8000 hematology automation line consisting of the BC-6800 and SC-120 (Photo courtesy of Mindray).
Image: The CAL 8000 hematology automation line consisting of the BC-6800 and SC-120 (Photo courtesy of Mindray).
The complete blood count and leukocyte differential count are the basic, most common tests in hematology laboratories. More tests can be performed at the same time; labor reduced, and results made more precise by an advanced automated hematology analyzer and slidemaker/stainer.

Reducing review of unnecessary blood film without missing true abnormal samples is the goal of automated hematology analyzers, because manual review increases laboratory cost, labor, and turnaround time. For the same reason, automated slidemaker/strainers demand quick, high-quality blood films.

Hematologists at the Gachon University Gil Medical Center (Incheon, Korea) selected 408 samples to evaluate a new hematology analyzer. Samples were collected from patients who needed a peripheral blood smear test by physicians' recommendation and from patients who had regular checkups. Two hundred of 408 samples showed flags, and 208 samples did not show any flags by the regular analyzer used in the laboratory.

The scientists compared the CAL 8000 (Mindray Bio-Medical Electronics Co, Ltd, Shenzhen, China) which is a cellular analysis line consisting of the Mindray BC-6800, an automated hematology analyzer, and the Mindray SC-120, an automated slidemaker/stainer and compared the analyzer results with the data from the XE-2100 automated hematology analyzer (Sysmex, Kobe, Japan) and the slidemaker with a manual method.

The team reported that most parameters measured by the BC-6800 matched well with the XE-2100 and manual differential. The flag efficiency of the BC-6800 for blasts (95.3%) and atypical lymphocytes (92.6%) were higher while immature granulocytes (89.7%) and nucleated red blood cells (94.1%) were lower than that of the XE-2100. Additionally, the BC-6800 detected four of five samples infected with malaria parasites. The SC-120 showed no carry-over and expected repeatability. There was good agreement on the five-part differential including abnormal cells between blood films by the SC-120 and manually prepared blood films. The shape of the red blood cells (RBC) was also comparable between blood films.

The authors concluded that the performance of BC-6800 was comparable with the XE-2100, and has a further advantage of detecting infection of malaria parasite. The SC-120 agreed well with manual differential and morphology assessment although the SC-120 needed the adjustment for stain precipitate and steaks. Therefore, the CAL-8000 is effective for precise, fast hematology work, and has useful application for malaria endemic areas. The study was published on September 23, 2016, in the Journal of Clinical Laboratory Analysis.

Related Links:
Gachon University Gil Medical Center
Mindray Bio-Medical Electronics
Sysmex
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The real-time multiplex PCR test is set to revolutionize early sepsis detection (Photo courtesy of Shutterstock)

1 Hour, Direct-From-Blood Multiplex PCR Test Identifies 95% of Sepsis-Causing Pathogens

Sepsis contributes to one in every three hospital deaths in the US, and globally, septic shock carries a mortality rate of 30-40%. Diagnosing sepsis early is challenging due to its non-specific symptoms... Read more

Pathology

view channel
Image: The QIAseq xHYB Mycobacterium tuberculosis Panel uses next-generation sequencing (Photo courtesy of 123RF)

New Mycobacterium Tuberculosis Panel to Support Real-Time Surveillance and Combat Antimicrobial Resistance

Tuberculosis (TB), the leading cause of death from an infectious disease globally, is a contagious bacterial infection that primarily spreads through the coughing of patients with active pulmonary TB.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.