We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




MRSA/SA PCR Rapid Test Quickly Diagnoses Methicillin Resistance at Point of Care

By LabMedica International staff writers
Posted on 06 Oct 2022
Print article
Image: Vivalytic test MRSA/SA provides quick diagnosis of methicillin resistance at POC (Photo courtesy of Bosch)
Image: Vivalytic test MRSA/SA provides quick diagnosis of methicillin resistance at POC (Photo courtesy of Bosch)

Methicillin-resistant (MRSA) is a major multi-resistant nosocomial pathogen worldwide with the WHO estimating that the mortality rate of patient infection rates is around 50% higher compared with patients who have been infected by non-resistant Staphylococcus aureus strains. Moreover, the extensive period of hospitalization, morbidity, and the associated medical costs increase significantly with an MRSA infection. The treatment on the front line today looks at increasing empirical antibiotic prescribing and increasing drug-resistant outbreaks. Speed is key here - since the result of diagnostics with culture sampling, which is the current traditional method for MRSA testing is only available after one to three days. Now, a new test for the quick diagnosis of MRSA at the point of the care not only provides rapid RT-PCR results in 53 minutes but differentiates whether the bacterial strain is MRSA or methicillin-sensitive (MSAA) which promotes targeted therapy.

The new MRSA/SA rapid test on Vivalytic by Bosch Healthcare Solutions GmbH (Waiblingen, Germany), a point of care platform brought to the market by Randox Laboratories (Crumlin, UK), delivers reliable results in under an hour directly at the point of care and is therefore, particularly suitable for use in accident and emergency units. Since the result of diagnostics with cultures is only available after one to three days, this PCR test for the point of care is ideal as an additional tool when speed is of the essence.

The quick and reliable diagnosis of whether the bacteria strain is MSSA or MRSA-resistant is also important in emergency situations. Waiting times for operations can, on the one hand, be reduced, while on the other enabling a decision on effective antibiotic treatment on this basis. This ability contributes to preventing contamination, breaking the chain of infection, and avoiding other resistances, which can, in turn, positively impact the treatment procedure and costs. Last but not least, unnecessary isolation measures, which are not only complex and expensive, but also put patients under even more pressure, can be avoided.

The advantages of PCR rapid tests administered with the aid of Bosch’s Vivalytic platform lie not only in the quick analysis time, but also in the ease of handling The Vivalytic system is a fully automated, cartridge-based platform capable of both Hi-Plex and Lo-Plex infectious disease testing. Each easy-to-use cartridge contains all necessary reagents, is fully-sealed to minimize risk and can be conveniently stored at room temperature. The Vivalytic consolidates the full molecular workflow into a small benchtop platform, capable of extraction, PCR amplification and detection. It follows an easy four step process from sample entry to results and with the gold standard PCR testing. With most up to date technology, the Vivalytic has wireless connectivity, with no peripherals required, making a unique space saving and hygienic solution. Handling and utilization are simple and medical professionals require only minimal training.

Related Links:
Randox Laboratories 
Bosch Healthcare Solutions GmbH 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.