Infrared Light Detects and Quantifies Malaria Parasites

By LabMedica International staff writers
Posted on 08 May 2014
A novel way to detect malaria, one of the most common and deadly diseases in the world, that also quantifies the early stage parasites, has been developed. More...


The quick and inexpensive test uses infrared light to detect malaria at a very early stage of its development by looking for fatty acids in the parasite and could dramatically reduce the number of people who die from the disease.

Scientists at Monash University (Clayton, VIC, Australia) maintained cultured Plasmodium falciparum parasites synchronized to ring stages by sorbitol lysis. High parasitemia ring-stage cultures were obtained by seeding uninfected red blood cells with purified schizont-stage parasites that were allowed to reinvade under shaking conditions overnight, reducing multiple infections.

The method to rapidly detect and quantify different stages of malaria parasites, including ring and gametocyte forms, used attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FT-IR) and partial least-squares regression (PLS). A Bruker model Equinox 55 (Bruker Optic; Ettingen, Germany) FT-IR spectrometer fitted with a nitrogen-cooled mercury–cadmium–telluride (MCT) detector and a golden gate diamond ATR accessory (Specac Limited; Orpington, UK) was used for spectral acquisition. ATR-FTIR utilizes infrared light to detect the vibrations of molecules and essentially depicts the entire chemistry of the system under investigation.

The scientists already knew that fatty acids were a marker for the disease from previous studies at the Australian Synchrotron. The Synchrotron allowed the team to see the different life stages of the parasite and the variation in its fatty acids. They then applied these insights to develop an inexpensive laboratory based test that has the potential to be portable. The results confirmed the ability of ATR-FT-IR to detect parasitaemia levels down to 0.00001%.

Bayden R. Wood, PhD, the senior author of the study, said, “Not only did the test give clear results within minutes, it gave a clear indication of malaria at a much earlier stage of infection than current tests on the market. Now that we can detect the early stages of a parasite's life in the blood stream the disease will be much easier to test and treat. The big advantage of our test is that it doesn't need scientists and expensive equipment. This has the potential to dramatically reduce the number of people dying from this disease in remote communities.” The study was published on April 2, 2014, in the journal Analytical Chemistry.

Related Links:

Monash University
Bruker Optic
Specac Limited



Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Serological Pipet Controller
PIPETBOY GENIUS
New
Gel Cards
DG Gel Cards
New
Sample Transportation System
Tempus1800 Necto
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








DIASOURCE (A Biovendor Company)

Channels

Molecular Diagnostics

view channel
Image: EvoLiver is the first test to receive FDA Breakthrough Device Designation in five years in the liver cancer surveillance space (Photo courtesy of Mursla Bio)

Patient-Friendly Blood Test to Transform Liver Cancer Surveillance

Hepatocellular carcinoma (HCC), the most common form of primary liver cancer, is the fastest-growing cause of cancer-related deaths. Although clinical guidelines recommend routine surveillance for high-risk... Read more

Hematology

view channel
Image: CitoCBC is the world first cartridge-based CBC to be granted CLIA Waived status by FDA (Photo courtesy of CytoChip)

Disposable Cartridge-Based Test Delivers Rapid and Accurate CBC Results

Complete Blood Count (CBC) is one of the most commonly ordered lab tests, crucial for diagnosing diseases, monitoring therapies, and conducting routine health screenings. However, more than 90% of physician... Read more

Immunology

view channel
Image: CellLENS enables the potential precision therapy strategies against specific immune cell populations in the tissue environment (Photo courtesy of MIT)

New AI System Uncovers Hidden Cell Subtypes to Advance Cancer Immunotherapy

To produce effective targeted therapies for cancer, scientists need to isolate the genetic and phenotypic characteristics of cancer cells, both within and across different tumors. These differences significantly... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.