Malaria Test Assessed in Nonendemic Setting

By LabMedica International staff writers
Posted on 23 May 2011
A rapid diagnostic test (RDT) for malaria has been evaluated in a standard reference laboratory using stored and fresh blood samples. More...


In nonendemic settings, where microscopic expertise is lacking due to low incidence, malaria RDTs are of value for the diagnosis of malaria and they provide information about the possibly fatal Plasmodium falciparum infections.

Scientists at Maastricht University, (Maastricht, The Netherlands), performed both a retrospective study on 341 stored blood samples and prospective study. In the prospective study, the SD Bioline Malaria Ag 05FK40, (SDFK40), RDT was used on 181 fresh samples and run side by side with two other RDTs, OptiMAL and SDFK60. The SDFK40 is a lateral flow antigen-detection test in a cassette format, targeting P. falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan-Plasmodium LDH, (pan-pLDH). The prospective part was performed between March 2009 and October 2010, and included first samples of each patient for which microscopy or one of the both routinely used RDTs (OptiMAL and SDFK60) were positive for malaria.

Overall sensitivities for P. falciparum tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities greater than 1,000/μL. Sensitivity at parasite densities less than 100/μL was 9.1%. Overall sensitivities for P. vivax and P. ovale were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities greater than 500/μL. Sensitivity for P. malariae was 21.4%. None of the Plasmodium negative samples in the retrospective panel reacted positive.

The authors concluded that SDFK40 RDT (Standard Diagnostics Inc.; Suwon, Korea), performed exceptionally for P. falciparum samples at high parasite densities as well as for detection of P. vivax and P. ovale at parasite densities greater than 500/μL. The SDFK40 was evaluated as easy to use, with an excellent clearance of the background and clearly visible test lines. Compared to OptiMAL Rapid Malaria test, (Diamed AG; Cressier, Switzerland), and Standard Diagnostics other RDT, called SD Bioline Ag Pf/Pan 05FK60 (SDFK60), SDFK40 showed lower sensitivities for P. falciparum, but better detection of P. ovale. The study was published online on January 12, 2011, in the Malaria Journal.

Related Links:
Maastricht University
Standard Diagnostics Inc.
Diamed AG



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Clinical Chemistry Assay
Sorbitol Dehydrogenase (SDH)
New
MR-proADM Test
B•R•A•H•M•S MR-proADM KRYPTOR test
Pipette Calibration System
Artel PCS®
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Nian Sun has spent years perfecting a device that he believes could change the way diseases are detected. (Photo courtesy of Alyssa Stone/Northeastern University)

Rapid Breath Sensor Detects SARS-CoV-2 from Exhaled Air

Nasal swabs and polymerase chain reaction (PCR) testing have been central to identifying SARS-CoV-2, but they can be uncomfortable, slow, and logistically complex when samples require transport.... Read more

Molecular Diagnostics

view channel
Image: At the MHH Institute of Human Genetics: Prof. Dr. Doris Steinemann, Dr. Bernardus Aldrige Allister and Prof. Dr Monika Golas (from left). (Image Credit: Karin Kaiser/MHH)

Multi-Omics Analysis Identifies Additional Risk Genes in Hereditary Breast and Ovarian Cancer

Hereditary breast and ovarian cancer can be difficult to explain genetically, leaving many high-risk families without clear answers. Although 13 established risk genes, including BRCA1 and BRCA2, are routinely... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.