Commercial System Effective for Cefiderocol Susceptibility Testing

By LabMedica International staff writers
Posted on 11 Jul 2019
Print article
Image: The Sensititre Complete Automated Antibiotic Susceptibility Testing (AST) System performs all susceptibility testing on a single platform utilizing the superior sensitivity of true MIC results (Photo courtesy of Thermo Fisher Scientific).
Image: The Sensititre Complete Automated Antibiotic Susceptibility Testing (AST) System performs all susceptibility testing on a single platform utilizing the superior sensitivity of true MIC results (Photo courtesy of Thermo Fisher Scientific).
The novel formulation of the cephalosporin antibiotic makes it very effective against gram-negative non-fastidious bacteria that are otherwise highly resistant to antibiotics, including carbapenem-resistant strains of Enterobacteriaceae and non-fermenters.

In microbiology, the minimum inhibitory concentration (MIC) is the lowest concentration of a chemical, usually a drug, which prevents visible growth of bacterium. MIC depends on the microorganism, the affected human being (in vivo only), and the antibiotic itself.

An international team of scientists working with Thermo Fisher Scientific (Cleveland, Ohio, USA) conducted a study that involved 374 recent clinical isolates, which included Escherichia coli, Klebsiella spp., Enterobacter spp., Citrobacter spp., Serratia marcescens, Pseudomonas aeruginosa, and Acinetobacter baumannii. One of the four study sites additionally used 147 Centers for Disease Control and Prevention challenge isolates. Three sites also used 11 reproducibility isolates, with three of these isolates being tested each day for three days. Finally, all four sites tested two quality control strains: E. coli ATCC 25922 and P. aeruginosa ATCC 27853.

The team tested a commercially prepared dried minimum inhibitory concentration (MIC) susceptibility system, the Thermo Fisher Scientific Sensititre, and demonstrated an equivalent level of performance compared with the Clinical & Laboratory Standards Institute (CLSI) M07/M100 and the International Organization for Standardization (ISO) 20776-1 reference broth microdilution (BMD) method when testing cefiderocol against Gram-negative non-fastidious organisms.

Overall agreement for the reproducibility (± 1 log2 dilution) concerning the most frequent (or modal) MIC value using automated and manual reading was 95.0% and 95.3%, respectively. The lowest agreement between the two test methods was 90.0% for Enterobacter spp., followed by 92.0% for Citrobacter spp. The strongest agreement was for P. aeruginosa (97.5%). The agreement among the four testing sites was high, at about 95%.

Thomas C. Lewis, BSc, a Research and Development Project Leader at Thermo Fisher Scientific, said, “The high level of agreement obtained by the Sensititre susceptibility system and the CLSI/ISO BMD method suggests that this is an acceptable method for susceptibility testing of cefiderocol. The results are available within 18 to 24 hours, versus several days for the broth. Plus, the testing materials can be kept on the laboratory shelf at room temperature before being used, which is a lot more convenient.” The study was presented at the Annual meeting of the American Society of Microbiology, held June 7-11, 2019, in Atlanta, GA, USA.

Related Links:
Thermo Fisher Scientific

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.