We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Olympus

Manufactures optical and digital equipment for the healthcare and consumer electronics sectors, including endoscopy a... read more Featured Products: More products

Download Mobile App




Fluorescent Reagents Evaluated for Vulvovaginal Candidiasis Diagnosis

By LabMedica International staff writers
Posted on 29 Jul 2021
Print article
Image: The images under fluorescence microscopy and light microscopy with four methods. A-D, show Candida albicans, and E-H, show C. glabrata; both the fungal color and the structure in FB 85 and CFW were clear and easily recognized from the background squamous cells compared with the KOH method (Photo courtesy of Capital Medical University)
Image: The images under fluorescence microscopy and light microscopy with four methods. A-D, show Candida albicans, and E-H, show C. glabrata; both the fungal color and the structure in FB 85 and CFW were clear and easily recognized from the background squamous cells compared with the KOH method (Photo courtesy of Capital Medical University)
Vulvovaginal candidiasis (VVC) is a common vaginitis in females, which is estimated to be the second most common cause of vaginitis after bacterial vaginosis. Vulvovaginal candidiasis affects around 70%–75% of all women during their childbearing age, and is considered to be an important public health problem.

The morbidity associated with VVC makes it a major cause of causing pain, great discomfort, mental distress, anxiety, altered self-esteem, impairing work performance and interfering with sexual and affective relations. The signs of VVC are typically characterized white clumpy discharge. The commonly used diagnostic method is 10% potassium hydroxide (KOH) smear microscopy.

Clinical Laboratorians at the Capital Medical University (Beijing, China) and their associates recruited patients according to the symptoms and the signs included vaginal discharge, irritation, itching, and/or odor, and who were suspected of having VVC, from October 2018 to February 2019. A total of 110 specimens were obtained with suspected VVC, aged 19–60 years, with an average age of 30.99 ± 7.77 years.

The team used different methods to detect VVC: fungal culture, fluorescent microscopy observation with Calcofluor White (CFW) and fluorescent brightener 85 (FB 85). The swabs were smeared on two separate slides, one with a drop of CFW, the other with a drop of 0.1% FB 85. The secretions gathered from the dilator were smeared on a third slide and examined using KOH under a light microscopy by adding a drop of 10% KOH to the slide. Microscopic observations were conducted using an Olympus CX23 LEDRFSIC microscopy (Olympus Co., Ltd, Tokyo, Japan) using either the 340–380 nm ultraviolet light mode or the visible light mode.

The scientists reported that in the 110 specimens, 75/110 (68.2%) were positive by the KOH method, 71/110 (64.5%) were positive by the CFW fluorescent method, 68/110 (61.8%) were positive by the FB 85 fluorescent method, and 77/110 (77%) were positive by the fungal culture method. In the 110 specimens, the specificity of the three methods was 100%. The sensitivity, and accuracy of CFW were the highest, followed by KOH method and FB 85 was the lowest.

For the VVC caused by Candida glabrata, yeast form was always observed, which is very clear with the CFW method and the FB 85 method, but was not easily found by light microscopy. The team observed a fade time of two fluorescent reagents under daylight in the room environment and due to the crystals and the faint fluorescence, it was harder to distinguish the fungi from the 24 hours specimen than the fresh specimen.

The authors concluded that they could find pathogenic fungi more quickly with fluorescent method in diagnosis of VVC. Both CFW and FB 85 were good reagents. FB 85 is a new fluorescent reagent for the diagnosis of VVC and other fungal affection diseases and has potential value for clinical applications. The study was published on July 12, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Capital Medical University
Olympus Co., Ltd


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.