Automated Hematologic Reference Intervals Defined for Newborns

By LabMedica International staff writers
Posted on 05 Jan 2021
Print article
Image: Hematologic Reference Intervals Defined for Newborns on the XN-1000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Image: Hematologic Reference Intervals Defined for Newborns on the XN-1000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Laboratory tests leverage 60% to 70% of medical decisions and one of the most often ordered and impactful tests is the complete blood count (CBC). These decisions require that clinicians have a standard for interpreting laboratory test results for their patients.

Ethical constraints exist for performing an unnecessary needle stick and collecting non-clinically indicated blood samples from this vulnerable newborn population. Many newborn CBC Reference Intervals (RI) publications have been retrospective and some authors cite this as one of their cardinal limitations.

A team of medical scientists associated with the Banner – University Medical Center Phoenix, (Phoenix, AZ, USA) conducted a prospective study at an academic tertiary care center, and hematology samples were collected from 120 participants deemed to be normal healthy term newborns. Study enrollment occurred between May 24, 2016, and November 1, 2017. A total of 170 blood specimens were sent to the laboratory.

The team used a single Sysmex XN-1000 Automated Hematology Analyzer (Sysmex America, Lincolnshire, IL, USA) to generate a CBC with white blood cell (WBC) differential for each newborn, including the advanced hematology parameters. Distributions were assessed for normality and tested for outliers. Reference intervals were values between the 2.5th percentile and 97.5th percentile.

The scientists reported that the novel reference intervals obtained for this study population are as follows: absolute immature granulocyte count, 80/μL to 1,700/μL; immature granulocyte percentage, 0.6% to 6.1%; reticulocyte hemoglobin equivalent, 31.7 to 38.4 pg; immature reticulocyte fraction, 35.9% to 52.8%; immature platelet count, 4.73 × 103/μL to 19.72 × 103/μL; and immature platelet fraction, 1.7% to 9.8%.

The authors concluded their prospective study has defined hematologic reference intervals for this newborn population, including new advanced clinical parameters from the Sysmex XN-1000 Automated Hematology Analyzer. These reference intervals are proposed as the new standard and can serve as a strong foundation for continued studies to further explore their value in diagnosing and managing morbidities such as sepsis, anemia, and thrombocytopenia. The study was published in the January, 2021 issue of the journal Archives of Pathology and Laboratory Medicine.

Related Links:
Banner – University Medical Center Phoenix
Sysmex America


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.