Fecal Immunochemical Test Assessed in Suspected Colorectal Cancer

By LabMedica International staff writers
Posted on 05 Nov 2020
Print article
Image: The HM-JACKarc analytical system is a compact bench top system that uses Integrated Sphere Latex Turbidimetry to measure fecal hemoglobin concentration using a highly sensitive latex reagent coated with polyclonal antibodies to human hemoglobin (Photo courtesy of Hitachi Chemical Diagnostics Systems).
Image: The HM-JACKarc analytical system is a compact bench top system that uses Integrated Sphere Latex Turbidimetry to measure fecal hemoglobin concentration using a highly sensitive latex reagent coated with polyclonal antibodies to human hemoglobin (Photo courtesy of Hitachi Chemical Diagnostics Systems).
Colorectal cancer (CRC), also known as bowel cancer, colon cancer, or rectal cancer, is the development of cancer from the colon or rectum (parts of the large intestine). Signs and symptoms may include blood in the stool, a change in bowel movements, weight loss, and fatigue.

The fecal immunochemical test (FIT) detects the globin component of hemoglobin (Hb) by immunoassay and can reliably measure the fecal Hb concentration (f-Hb) to the nearest microgram of Hb per gram of faces (µg/g). Since 2010, over 25 diagnostic accuracy studies have reported data on the use of FIT in symptomatic patients utilizing a range of cut-offs.

A team of medical scientists led by those at Croydon University Hospital (Croydon, UK) analyzed almost 10,000 patients referred to a specialist for suspected CRC symptoms that met criteria for urgent care. FIT sensitivity was maximized to 97.0% at the lowest fecal hemoglobin concentration cutoff of 2 µg/g. Between October 2017 and December 2019, 21,126 patients were sent recruitment packs, 13,219 (62.6%) returned FIT devices. Complete FIT and colonoscopy outcomes were available for 9,822 patients, who were included in the study results. Median age was 65 in the final cohort of kit-returning patients, 54% of whom were women.

FIT analysis was performed at one centralized laboratory where staff were blinded to patient clinical information. The HM-JACKarc analytical system (Hitachi Chemical Diagnostics Systems, Tokyo, Japan) was used to analyze all samples. The analytical working range is 7–400 µg/g. The limit of detection (LoD) of the assay is 2 µg/g and the limit of quantitation is 7 µg/g. The National Institute for Health and Care Excellence (NICE) recommended an f-Hb cut-off of 10 µg/g in the DG30 guidelines. Colonoscopy was chosen as the reference standard since it is acknowledged to be the gold-standard investigation for colorectal disease. Colonoscopists were blinded to the FIT results.

The team reported that incidence of CRC at colonoscopy was 3.3%. At fecal hemoglobin concentration cutoffs of 2, 10, and 150 µg/g, FIT positivity decreased from 37.2% to 19.0% and 7.6%, respectively. The positive predictive values of FIT for CRC was 8.7% at the 2 µg/g cutoff, 16.1% at the 10 µg/g cutoff, and 31.1% at the 150 µg/g cutoff. Respective negative predictive values were 99.8%, 99.6%, and 98.9%. In terms of sensitivity for CRC, this decreased from 97.0% at the 2 µg/g cutoff, to 90.9% at the 10 µg/g cutoff, and 70.8% at the 150 µg/g cutoff. Specificity increased from 64.9% to 83.5% and 94.6%, respectively.

The authors concluded that a higher hemoglobin cutoff could be set to match capacity in resource-limited settings, which would reduce the number of positive results, onwards referral for investigation and demand for colonoscopy but at the expense of detecting fewer cancers. The study was published on October 21. 2020 in the journal GUT.

Related Links:
Croydon University Hospital
Hitachi Chemical Diagnostics Systems


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ASTar System has received US FDA 510(k) clearance (Photo courtesy of Q-linea AB)

Automated Sepsis Test System Enables Rapid Diagnosis for Patients with Severe Bloodstream Infections

Sepsis affects up to 50 million people globally each year, with bacteraemia, formerly known as blood poisoning, being a major cause. In the United States alone, approximately two million individuals are... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.