We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Padlock Probe Assay Rapidly Detects Cardiac Disease Gene Mutations

By LabMedica International staff writers
Posted on 25 Aug 2015
Print article
A recent paper described a novel next generation sequencing (NGS) assay for detecting cardiac disease gene mutations with improved accuracy, flexibility, turnaround time, and cost.

By using double-stranded DNA probes (complementary long "padlock" probes or cLPPs), investigators at Stanford University (Palo Alto, CA, USA) reduced the scale of analysis needed to diagnose hereditary cardiovascular abnormalities. The current method involves sequencing thousands of genes, costs USD 1,000 or more per patient, and requires weeks or months to obtain results. The cLPP-based method analyzes only the 88 genes known to carry heart defect mutations, costs about USD 100 per patient, and returns results within three days.

cLPPs are long oligonucleotides of around 100 bases, containing target complementary regions at both their 5′ and 3′ ends. These regions recognize adjacent sequences on the target DNA and between these segments lie universal primer sites and a unique sequence identifier, the so-called ZipCode. Upon hybridization, the ends of the probes get into adjacent position and can be joined by enzymatic ligation. This ligation and the resulting circular molecule can only take place when both end segments recognize their target sequences correctly. Non-circularized probes are removed by exonuclease treatment, while the circularized ones may be amplified by using universal primers. Subsequently, the target-specific products are detected by a universal complementary ZipCode (cZipCode) microarray. cLPPs have been shown to possess good specificity and very high-multiplexing capabilities in genotyping assays.

The investigators reported in the August 11, 2015, online edition of the journal Circulation Research that they had used cLPPs to capture and amplify the entire coding region and flanking intronic and regulatory sequences of 88 genes and 40 microRNAs (miRNA) associated with inherited cardiac abnormalities, congenital heart disease (CHD), and cardiac development. The assay correctly detected germline variants in 24 individuals and revealed several polymorphic regions in miR-499.

This new technique could eventually enable doctors to diagnose genetic heart diseases by rapidly scanning the 88 genes known to cause cardiac anomalies. Senior author Dr. Joseph Wu, professor of cardiovascular medicine and radiology at Stanford University, said, “Suppose you have a 60-year-old patient who comes in with heart failure. We do the angiogram and we find he has no history of heart attack or other issues, and yet the heart is not performing well. We also find that several of his family members have similar heart conditions. So if we run the new genetic test and find the man’s illness has a genetic cause, such as dilated cardiomyopathy, we now have both a cause and a diagnosis, and we can initiate treatment right away.”

Related Links:

Stanford University


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.