We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Events

ATTENTION: Due to the COVID-19 PANDEMIC, many events are being rescheduled for a later date, converted into virtual venues, or altogether cancelled. Please check with the event organizer or website prior to planning for any forthcoming event.

Novel Non-Sputum Based Technology Quickly and Easily Detects Active TB

By LabMedica International staff writers
Posted on 16 Mar 2023
Print article
Image: Researchers have discovered a new technology that will quickly and easily detect active TB infection antibodies (Photo courtesy of Wayne State University)
Image: Researchers have discovered a new technology that will quickly and easily detect active TB infection antibodies (Photo courtesy of Wayne State University)

TB, caused by Mycobacterium tuberculosis, is a serious global health concern that results in 10 million new cases and 1.7 million deaths annually. According to the latest report by the World Health Organization, TB is the 13th leading cause of death worldwide, and the second leading infectious disease killer after COVID-19. The presence of Latent Tuberculosis Infection (LTBI) is a critical issue, as it serves as a reservoir for TB bacteria and increases the risk of developing active TB. Alarmingly, one-third of the world's population is infected with TB, and 5 to 10% of those with LTBI will progress to active TB within the first five years after initial infection.

The current gold standard diagnostic tests for detecting active TB infection are the sputum smear and culture tests. Unfortunately, these methods have several limitations, including the need for collecting sputum, trained personnel, cost, lengthy processing time, and inadequate sensitivity. Similarly, conventional tests for differentiating latent TB from uninfected individuals, such as tuberculin skin tests (TST) and interferon gamma release assays (IGRA), are not effective in distinguishing active TB from latent infection. Despite advancements in rapid molecular diagnostic techniques for TB, there remains a significant need for a time-efficient, cost-effective, and non-sputum-based point-of-care (POC) test. Now, researchers at Wayne State University (Detroit, MI, USA) have discovered a new technology that can rapidly and easily detect active TB infection antibodies.

For over 15 years, a dedicated research group at Wayne State has been focusing on developing technology for detecting antibodies related to various respiratory diseases. The team has successfully created an innovative non-sputum-based approach and identified multiple novel immune-epitopes that differentially bind to specific immunoglobulin (IgG) found in individuals who are infected with TB. By measuring the levels of epitope-specific IgG in the serum, this breakthrough technology can distinguish active TB from LTBI subjects, healthy individuals, and other respiratory diseases. This simple and non-sputum-based serological POC-TB test is highly sensitive and specific, making it an ideal option to differentiate active TB from LTBI.

The researchers had earlier developed a T7 phage antigen display platform and after immunoscreening of large sets of serum samples, they identified 10 clones that differentially bind to serum antibody (IgG) of active TB patients differentiating TB from other respiratory diseases. One of these high-performance clones had homology to the Transketolase (TKT) enzyme of TB bacteria that is an essential enzyme required for the intracellular growth of the bacteria in a host. The researchers hypothesized that abundance of IgG in sera against the identified novel neoantigen that they named as TKTµ could differentiate between active TB, LTBI and other non-TB granulomatous lung diseases like sarcoidosis. The team developed a novel direct Peptide ELISA test to quantify the levels of IgG in serum samples against TKTµ. The research team designed two additional overlapping M.tb TKT-peptide homologs with potential antigenicity corresponding to M.tb-specific transketolase (M.tb-TKT1 and M.tb-TKT3) and hence standardized three Peptide ELISA (TKTμ, M.tb TKT1 and M.tb TKT3) for the TB serodiagnosis.

After development and standardization of a direct peptide ELISA for three peptides, the research team tested 292 subjects, and their TKT-peptide ELISA results revealed that TB patients had significantly higher levels of TKT-specific antibodies than healthy controls or those with LTBI. The higher levels of TKT-specific antibodies can be attributed to growing M.tb bacteria in active TB patients. TKT plays a crucial role in the transition from the dormant to the proliferative phase, and TKT specific IgG can reveal differences between active TB and LTBI. Consequently, IgG-based serodiagnosis of TB utilizing TKT-peptide ELISA holds promise. The current commercially available serological TB tests exhibit inadequate sensitivity and specificity. However, the ELISA results from the newly discovered TKT peptides demonstrated high sensitivity and specificity. The research team's findings indicate that IgG antibodies against transketolase have the potential to distinguish active tuberculosis.

“Our TKT peptide ELISA test requires chemically synthesized TKT peptides to coat the wells in the ELISA plate, less than 100µl blood serum sample from patient, detection reagents and an ELISA plate reader,” said Lobelia Samavati, M.D., professor in the Center for Molecular Medicine and Genetics in the School of Medicine, who led the research team. “We are extremely enthusiastic about our technology and the fact that with a simple test we can differentiate active TB from LTBI and other respiratory diseases. We believe that our method and TKT peptide ELISA can fit the requirements of the World Health Organization and the Centers for Disease Control and Prevention as a POC screening method.”

Related Links:
Wayne State University

Flocked Swab
HydraFlock and PurFlock Ultra
Gold Supplier
COVID-19 Antigen Self-Test
Panbio COVID-19 Antigen Self-Test
New
Portable Coagulation Monitor
VCM
New
Spectrophotometer
UVILINE 9300

Print article

Channels

Clinical Chem.

view channel
Image: Electrochemical cells etched by laser on wooden tongue depressor measure glucose and nitrite in saliva (Photo courtesy of Analytical Chemistry)

Biosensor-Fabricated Wooden Tongue Depressor Measures Glucose and Nitrite in Saliva

Physicians often use tongue depressors to examine a patient's mouth and throat. However, it is hard to imagine that this simple wooden tool could actively assess a patient's health. This idea has led to... Read more

Molecular Diagnostics

view channel
Image: A portable smartphone-based POC device for use with EXTRA-CRISPR method for cancer diagnostics (Photo courtesy of UF Health)

CRISPR-Powered Method for Non-Invasive Blood Tests to Help Diagnose Early Stage Cancer

MicroRNAs, tiny RNA molecules that regulate gene expression, have been identified as potential cancer biomarkers in human fluids like blood. Extracellular vesicles, tiny particles actively discharged by... Read more

Hematology

view channel
Image: The Atellica HEMA 570 and 580 hematology analyzers remove workflow barriers (Photo courtesy of Siemens)

Next-Gen Hematology Analyzers Eliminate Workflow Roadblocks and Achieve Fast Throughput

Hematology testing is a critical aspect of patient care, utilized to establish a patient's health baseline, track treatment progress, or guide timely modifications to care. However, increasing constraints... Read more

Immunology

view channel
Image: Newly observed anti-FSP antibodies have also been found to predict immune-related adverse events (Photo courtesy of Calviri)

First Blood-Based Biomarkers Test to Predict Treatment Response in Cancer Patients

Every year worldwide, lung cancer afflicts over two million individuals and almost the same number of people succumb to the disease. This malignancy leads the charts in cancer-related mortalities, with... Read more

Microbiology

view channel
Image: The rapid MTB strip test for tuberculosis can identify TB patients within two hours (Photo courtesy of Chulalongkorn University)

Rapid MTB Strip Test Detects Tuberculosis in Less Than an Hour without Special Tools

Tuberculosis (TB), a highly infectious disease, continues to pose significant challenges to public health worldwide. TB is caused by a bacterium known as "Mycobacterium tuberculosis," spreading through... Read more

Pathology

view channel
Image: The UNIQO 160 (CE-IVDR) advances diagnostic analysis for autoimmune diseases (Photo courtesy of EUROIMMUN)

Novel Automated IIFT System Enables Cutting-Edge Diagnostic Analysis

A newly-launched automated indirect immunofluorescence test (IIFT) system for autoimmune disease diagnostics offers an all-in-one solution to enhance the efficiency of the complete IIFT process, comprising... Read more

Technology

view channel
Electronic biosensor uses DNA aptamers for detecting biomarkers in whole blood samples (Photo courtesy of Freepik)

Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents

The absence of robust, reliable, and user-friendly bioanalytical tools for early and timely diagnosis of cardiovascular diseases, particularly sudden cardiac arrest, leads to preventable deaths and imposes... Read more

Industry

view channel
Image: The global hemostasis diagnostics market is expected to reach USD 3.95 billion by 2025 (Photo courtesy of Freepik)

Global Hemostasis Diagnostics Market Driven by Increase in Invasive Surgical Procedures

Injury or surgery naturally creates bleeding in living beings, which must be stopped to prevent excessive blood loss. The human body implements a protective mechanism known as hemostasis to stop excessive bleeding.... Read more
Copyright © 2000-2023 Globetech Media. All rights reserved.