We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Kidney Transplant Rejection Linked to New Mismatch Locus

By LabMedica International staff writers
Posted on 13 Jun 2019
Print article
Image: The NimbleGen MS 200 CGH LOH microarray detection scanner (Photo courtesy of Roche).
Image: The NimbleGen MS 200 CGH LOH microarray detection scanner (Photo courtesy of Roche).
Approximately 20% of the kidney waiting list in the USA consists of candidates whose allografts have failed. Acute rejection is one of the strongest predictors of decreased allograft survival.

In the context of kidney transplantation, genomic incompatibilities between donor and recipient may lead to allosensitization against new antigens. A new form of genetic mismatch, or “genomic collision”, has been identified between kidney transplant recipients and organ donors that appears to increase the risk of allograft rejection.

A large team of scientists led by those at Columbia University (New York, NY, USA) performed a two-stage genetic association study of kidney allograft rejection. The study aimed at uncovering high-priority copy number variants influencing kidney allograft rejection in more than 700 transplant recipients. In particular, they focused on the so-called genomic collision situations, in which transplant recipients carried two copies of a deletion that was not homozygous in the organ donor.

The identification of alloantibodies was performed with the use of protein arrays, enzyme-linked immunosorbent assays (ELISAs), and Western blot analyses. The team used the NimbleGen array-based comparative genome hybridization to search for 50 suspicious deletions affecting protein-coding parts of the genome in 705 kidney transplant recipients. From there, they searched for associations with kidney allograft rejection in a “time-to-event survival analysis” in the patients, who were followed for more than eight-and-a-half years, on average.

In the discovery cohort, which included 705 recipients, they found a significant association with allograft rejection at the LIMS1 locus represented by rs893403 (hazard ratio with the risk genotype versus the non-risk genotypes, 1.84). This effect was replicated under the genomic-collision model in three independent cohorts involving a total of 2,004 donor–recipient pairs (hazard ratio, 1.55). In the combined analysis (discovery cohort plus replication cohorts), the risk genotype was associated with a higher risk of rejection than the non-risk genotype (hazard ratio, 1.63). The team identified a specific antibody response against LIMS1, a kidney-expressed protein encoded within the collision locus. The response involved predominantly IgG2 and IgG3 antibody subclasses.

The team got further evidence for the hypothesis following a functional analysis of the rejection-related risk variant, and sero-reactivity experiments that relied on protein array data for hundreds more kidney transplant recipients who did or did not experience allograft rejection. The authors noted that the LIMS1 protein also appears to be expressed in other commonly transplanted organs, including the heart and lung, though they cautioned that follow-up studies will be useful in determining whether our findings are generalizable to other organs. The study was published on May 16, 2019, in The New England Journal of Medicine.

Related Links:
Columbia University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.