We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
LGC Clinical Diagnostics

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Factor IX Inhibitor Incidence in Pediatric Hemophilia B Examined

By LabMedica International staff writers
Posted on 20 Feb 2020
Print article
Image: The VisuLize Factor XI ELISA Kit is an Enzyme Immunoassay for the quantitative determination of Factor XI Antigen in human plasma samples using the double antibody enzyme linked immuno-sorbent assay (ELISA) (Photo courtesy of Affinity Biologicals, Inc).
Image: The VisuLize Factor XI ELISA Kit is an Enzyme Immunoassay for the quantitative determination of Factor XI Antigen in human plasma samples using the double antibody enzyme linked immuno-sorbent assay (ELISA) (Photo courtesy of Affinity Biologicals, Inc).
Hemophilia B is a blood clotting disorder causing easy bruising and bleeding due to an inherited mutation of the gene for factor IX, and resulting in a deficiency of factor IX. It is less common than factor VIII deficiency (hemophilia A).

Specific genetic changes may account for a larger proportion than previously thought of children with severe hemophilia B who develop inhibitors against coagulation factor IX replacement therapy. Factor IX replacement therapy is standard for hemophilia B patients to supply them with the missing clotting factor. However, some patients, almost exclusively those with severe disease, develop inhibitors (an immune response) against the therapy which can severely block its effectiveness and lead to treatment resistance.

An international team of scientists led by the Medical University of Vienna (Vienna, Austria) evaluated the frequency of inhibitor development and allergic reactions in children with severe hemophilia B, as well as the effect of F9 mutations on the risk of developing inhibitors, using data from the PedNet Haemophilia Registry (Baarn, in The Netherlands). The team analyzed the demographic and clinical data of 154 untreated children with severe hemophilia B for up to 500 days of primary prophylaxis (preventive replacement treatment at an early age, before symptom onset).

During the first 50 days of treatment, and then annually, detailed data was collected about the presence of inhibitors (at least two consecutive blood samples positive for inhibitors) and allergic reactions. Most children (80%) were Caucasian, and about half of them had a history of hemophilia in the family. The children started preventive treatment at a median age of 9.6 months, and 77% of them were followed until 50 days of treatment, 75% until 75 days, 68% until 150 days, and 43% until 500 days of treatment.

The scientists reported that that 14 children (9%) developed factor IX inhibitors during the study, at a median of 11 days of treatment and when they were nearly 2 (23.2 months). Seven of them showed considerably high levels of inhibitors. The cumulative frequency of inhibitor development at 75 days of treatment was 9.3% for all levels of inhibitors and 5% for high levels of inhibitors. At 500 days of treatment, the frequency of inhibitor development was 10.2%. A positive family history for factor IX inhibitors was significantly more frequent (21%) among children positive for inhibitors than among those who did not develop inhibitors.

Analysis of available genetic data from 124 children (80.5%) showed that the most frequent mutations were missense mutations (46.8%). However, these mutations were not associated with the development of inhibitors; for the 14 inhibitor-positive children, seven carried only nonsense mutations (50%), and five had large genetic deletions (35.7%). Nonsense mutations result in a premature stop in protein production, leading to a shorter and likely nonfunctional protein. Two children had no known genotype.

The data showed that the risk of developing inhibitors was increased by 26.9% in children carrying nonsense F9 mutations and by 33.3% in those carrying large F9 deletions. The team hypothesized that the high proportion of missense mutations (resulting in some levels of factor IX protein) in severe hemophilia B patients is behind the overall low frequency of inhibitor development, compared to that of hemophilia A patients (25%–35%). In addition, allergic reactions associated with inhibitor development were reported in four children (28.6%), one of them having high levels of factor IX inhibitors. Two of them carried nonsense mutations, one had a large deletion, and one had an unknown mutation.

The study was published on January 9, 2020 in the journal Haematologica.

Related Links:
Medical University of Vienna
PedNet Haemophilia Registry


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.