Different Methods Compared for Species Identification of Enterococcus

By LabMedica International staff writers
Posted on 18 May 2020
Print article
Image: The BD Phoenix M50 Automated Microbiology System provides clinicians with accurate and timely identification and susceptibility results to help guide their therapy and patient management decisions (Photo courtesy of Becton‐Dickinson).
Image: The BD Phoenix M50 Automated Microbiology System provides clinicians with accurate and timely identification and susceptibility results to help guide their therapy and patient management decisions (Photo courtesy of Becton‐Dickinson).
Biochemical test‐based methodologies are still used in some laboratories for the identification of bacterial isolates, mainly because of the need for the performance of drug susceptibility tests. However, these systems are unable to distinguish some species, especially among Gram‐positive bacteria.

Matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an efficient method used in clinical microbiology laboratories for the identification of clinically relevant microorganisms. Microorganisms can be identified using a reference database in a turnaround time of minutes, which is essential when rapid results are needed.

Medical Scientists at the Universidad Autónoma de Nuevo León (Monterrey, Mexico) evaluated the performance of two commercial MALDI‐TOF MS systems and three biochemical‐based systems and compared them to whole genome sequencing (WGS) as the gold standard for identifying isolates of vancomycin‐resistant enterococci (VRE). A total of 87 VRE clinical isolates recovered from urine (33%), soft tissue (24%), blood (16%), and other specimens (27%) were identified by the systems.

For both MALDI‐TOF instruments, the direct method was used for identification. The mass spectrometers were the Microflex system with Biotyper software 3.1 (Biotyper; Bruker Daltonics, Bremen, Germany) and the Vitek MS system (bioMérieux, Marcy l'Etoile, France). The biochemical‐based systems included the bioMérieux Vitek 2, Phoenix (Becton‐Dickinson, Franklin Lakes, NJ, USA), and MicroScan WalkAway (Siemens Healthcare Diagnostics, Munich, Germany) systems. Paired‐end sequencing runs were performed on an Illumina MiSeq instrument (Illumina, San Diego, CA, USA).

The scientists reported that among the 87 VRE, 71 and 16 were identified as Enterococcus faecium and Enterococcus faecalis by WGS. All 71 E. faecium were correctly identified by both mass spectrometers, as well as the Vitek 2 and Phoenix instruments. However, only 51 E. faecium isolates were correctly identified by the MicroScan system. The most frequent misidentification was Enterococcus casseliflavus (n = 20). For vancomycin‐resistant E. faecium, the Microflex Biotyper system had the highest sensitivity (85.54%), and all instruments (except for the MicroScan) had a 100% specificity and positive predictive value (PPV). Up to 87% of E. faecalis isolates were misidentified by VITEK MS and VITEK2, 81% by MicroScan and Phoenix, and 75% by Bruker biotyper. The NPV was lower than 38% for all devices. The instrument with the highest accuracy was the Bruker Biotyper system (86.21%).

The authors concluded that as the coverage of type strain‐genome sequence database continues to grow and the cost of DNA sequencing continues to decrease, genome‐based identification can be a useful tool for diagnostic laboratories, with its superior accuracy even over MALDI‐TOF and database‐driven operations. The study was published on May 1, 2020 in the Journal of Clinical Laboratory Analysis.



Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.