We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Diagnostic Performance of Blood Counts Compared

By LabMedica International staff writers
Posted on 17 Oct 2017
Print article
Image: The ADVIA 2120 hematology analyzer (Photo courtesy of Siemens Healthcare).
Image: The ADVIA 2120 hematology analyzer (Photo courtesy of Siemens Healthcare).
The use of point-of-care testing is increasing, however many hematology analyzers can only determine granulocyte count without further differentiation into neutrophils, eosinophils and basophils.

The technology of morphological assessment and counting of blood cells has advanced over recent decades, particularly in the white cell lineage, with concomitant benefits in relation to diagnosis, prognosis and management of inflammatory and malignant conditions. The full range of measurements is available on modern automated laboratory analyzers.

Laboratory scientists at the Leeds Institute of Health Science (Leeds, UK) conducted an analysis on a pseudonymised, retrospective database containing peripheral venous blood sample results between 1 January 2004 and 1 September 2013 from 21,020 patients, all of whom had received chemotherapy treatment. Blood counts were measured from EDTA venous whole blood samples obtained for the purposes of routine clinical care, and taken at any time in relation to chemotherapy delivery.

All samples were submitted for a full blood count analysis, including a five-part differential on a Siemens ADVIA 120 analyzer (Siemens Healthcare Diagnostics, Erlangen, Germany) until August 2004 and subsequently on the Siemens ADVIA 2120 analyzer; both instruments employ the same method principles. Data of interest included the eosinophil, basophil and neutrophil counts, with the sum of these three parameters being taken as the granulocyte count and lymphocyte and monocyte results were also extracted for analysis.

The team found that granulocyte to neutrophil count correlation was 0.997. The accuracy for classification into neutropenia grades using the derived equivalent granulocyte count ranges was 96.4%. Identification of results with a neutrophil count less than 1.5×109 cells/L using an equivalent granulocyte count of less than 1.69×109 cells/L resulted in sensitivity, specificity, positive and negative predictive values of 98.0%, 99.5%, 97.8% and 99.5%, respectively.

The authors concluded that their results describe the relationship between granulocyte and neutrophil counts, measured on a laboratory analyzer, in a large population of patients with malignancies and receiving anti-cancer therapies. However, this relationship must be established using a point of care testing system with a three-part differential count before considering the possibility that a granulocyte count can guide clinical decisions in the absence of a definitive neutrophil count, to reduce the frequency and severity of neutropenic complications in patients receiving cancer treatments. The study was published on October 4, 2017, in the journal Practical Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.