We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

WERFEN

Werfen provides diagnostic instruments for critical care and hemostasis to meet the testing needs of medical professi... read more Featured Products: More products

Download Mobile App




Capillary and Venous Blood Sampling Compared for Coagulation Assays

By LabMedica International staff writers
Posted on 17 Mar 2022
Print article
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)
Image: The ACL-TOP 750 LAS coagulation analyzer (Photo courtesy of Werfen)

Clinical laboratories offer a wide range of coagulation assays used in the diagnosis and management of patients with hemostatic disorders, preoperative screening, or anticoagulation therapy monitoring.

The request from clinicians for capillary blood collection for other routine coagulation test, such as International Normalized Ratio, prothrombin time, activated partial thromboplastin time, and thrombin time, remains significant in particular from those involved in pediatrics. Capillary sampling offers a less invasive method for blood collection than venipuncture, which makes it more suitable for neonates, young children as well as for adult patients with poor venous access or severe anxieties concerning blood sampling.

Diagnostic Laboratorians at the University Medical Center Utrecht (Utrecht, The Netherlands) performed a method comparison between capillary and venous blood sampling for routine coagulation assays. Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen, Bedford, MA, USA) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error.

The scientists reported that there was a strong correlations and acceptable variations, using the total allowable error (TEa) as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling, However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of −10.4%.. The mean relative difference of TT and fibrinogen was −1.7% and −3.7%, respectively, but were considered acceptable variations using the TEa as a decision limit. D-dimer showed a mean relative difference of 1.2%], which fell within the range of acceptable variation.

The authors concluded that strong correlations and acceptable variations were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significantly shorter APTT values when using the standard APTT-SP Liquid reagent. Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable. The study was originally published online on February 3, 2022, in the journal Clinical Biochemistry.

Related Links:
University Medical Center Utrecht 
Werfen 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.