D-Dimer Efficacy Evaluated for Disseminated Intravascular Coagulation Diagnosis

By LabMedica International staff writers
Posted on 17 Feb 2016
Print article
Image: Sysmex C-1500 automatic coagulation analyzer (Photo courtesy of Siemens Healthcare).
Image: Sysmex C-1500 automatic coagulation analyzer (Photo courtesy of Siemens Healthcare).
Image: The Innovance D-Dimer reagent set (Photo courtesy of Siemens Healthcare).
Image: The Innovance D-Dimer reagent set (Photo courtesy of Siemens Healthcare).
Disseminated intravascular coagulation refers to an acquired syndrome characterized by procoagulant substances entering the general circulation and leading to a systemic thrombotic process, which may be derived from or causing microvascular system damage.

D-dimer (D-D) was shown to be an important indicator for the diagnosis of overt disseminated intravascular coagulation (DIC) and non-overt DIC; however, its diagnostic cutoff value in the clinic is not clearly defined. The initiation of treatment in nonovert DIC leads to better outcome than in DIC and therefore, early diagnosis of non-overt DIC is pivotal for DIC prevention and treatment.

Clinical scientists at the Nanjing Medical University (Suzhou, China) enrolled 40 male and 80 female cases in each group (DIC, non-overt DIC, and non-DIC control group). All 360 cases were collected in Suzhou Municipal Hospital. The DIC group included patients clearly diagnosed with DIC who had been hospitalized in the intensive care unit (ICU); the non-overt DIC group comprised patients who were diagnosed later as DIC; and the non-DIC control group included patients who were convalescing after surgery, had normal liver and kidney function.

D-D, fibrinogen degradation products (FDP), prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (Fg), thrombin time (TT), antithrombin (AT), and blood platelet count (PLT) of 360 cases were used to assess the diagnostic efficacy of Innovance D-Dimer reagent (Siemens Healthcare Diagnostics, Erlangen, Germany) for the diagnosis of DIC and non-overt DIC, compared to, or combined with, other DIC coagulation indicators. D-D was quantitatively analyzed using a Sysmex CA1500 automatic coagulation analyzer (Sysmex Corporation; Kobe, Japan) with an immunoturbidimetric method.

The investigators found that when D-D was greater than 3.0 μg/mL was used as the cutoff, the sum of diagnostic sensitivity and specificity reached maximum values for DIC and non-overt DIC, whereas the sum of misdiagnoses and missed diagnosis rate was minimal. Excluding D-D, AT, or Fg, but not TT, from the test combination reduced the diagnostic sensitivity of DIC or non-overt DIC by various degrees. Combining two factors, D-D of greater than 3.0 μg/mL and FDP of greater than 10 mg/L, increased the sensitivity and specificity for the diagnosis of DIC and non-overt DIC.

The authors concluded that monitoring D-D and FDP levels is useful for early intervention and improving microcirculation disturbance caused by disease. They propose that a cutoff value of D-D of greater than 3.0 μg/mL would be suitable for the InnovanceR D-D reagent in the laboratory; D-D in combination with FDP is meaningful for primary screening of non-overt DIC. The study was published on February 2, 2016, in the International Journal of Laboratory Hematology.

Related Links:

Nanjing Medical University 
Siemens Healthcare Diagnostics 
Sysmex Corporation 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.